8.2.1 Functionality verification
▶ Verify the good working order of all the elements.
8.2.2 Magnesium Anode
▶ Before starting, verify that the appliance is disconnected
from the electric current.
▶ Completely drain the appliance (
Chapter 6.3).
▶ Remove the lid of the appliance.
Fig. 13
▶ Switch off the circuit breaker feeding the appliance.
▶ Disconnect the connecting cables to the thermostat
▶ Loosen the fastening screws of the flange [1].
▶ Remove the flange [2].
▶ Verify the magnesium anode [3] and replace it if necessary.
CAUTION:
Damages to the glass enamel!
Never clean the enamel interior of the
appliance with decalcifying agents. The
magnesium anode ensures anti corrosion
protection. There is no need for alternative
products for the protection of the enamel.
This appliance disposes of an anti-corrosion
magnesium anode in the inside.
WARNING:
It is forbidden to operate the appliance
without an installed magnesium anode.
WARNING:
The magnesium anode needs to be annually
tested and replaced if necessary, failing to
do so will result in the termination of the
warranty. The appliance without this type of
protection will not be covered by the
manufactures warranty.