background image

12

Use

TR2000T – 6 720 885 113 (2018/04)

6

Use

Fig. 11

User interface

[1] Operating light
[2] On / Off switch
[3] Temperature selector

6.1

Turning the appliance on/off

Turn on

▶ Switch to „I“.

Turn off

▶ Switch to „0“.

6.2

Setting the DHW temperature

The water outlet temperature can be regulated until 70 °C.

Increasing the temperature

▶ Turn the temperature selector to the right.

Decreasing the temperature

▶ Turn the temperature selector to the left.

6.2.1 „Anti-Frost“-mode -

In this mode, the hot water tank always starts, when the 
temperature inside the hot water tank reaches 5 °C.

▶ Switch to „

-

“.

6.3

Emptying the appliance

▶ Turn off the appliance from the electric supply.

▶ Switch off the water cutting valve and open a hot water tap.
▶ Open the safety valve (Fig. 12).
▶ Wait until the appliance is completely empty.

Fig. 12

Manual activation of the safety valve

CAUTION: 

The first start-up of the appliance 

must be carried out by an authorized 
technician, which will provide the user with 
all the necessary information to the best 
working and handling of the device.

Once the water has reached the selected 
temperature level, the appliance stops 
heating up (the indicator switches off). 
When the water temperature is below the 
desired value, the appliance re-starts the 
heating cycle (the indicator switches back 
on) until it reaches the desired temperature 
selected.

2

3

1

67

2

08

21

79

1

-0

3

. V

2

DANGER: 

Burn risk!

Open a hot water tap to and verify the 
temperature of the water in the appliance 
before opening the safety valve.

▶ Wait until the water temperature 

decreases in order to avoid burns or any 
other damage.

6720643873-06.1V

Summary of Contents for TR2000T 10

Page 1: ...User and Installation manual Electrical storage water tank TR2000T TR2000T 10 15 6 720 885 113 2018 04 DIV ...

Page 2: ...iance 9 5 3 Water connection 10 5 4 Electrical connections 11 5 5 Start up 11 6 Use 12 6 1 Turning the appliance on off 12 6 2 Setting the DHW temperature 12 6 2 1 Anti Frost mode 12 6 3 Emptying the appliance 12 7 Environment disposal 13 8 Inspection Maintenance 13 8 1 User information 13 8 1 1 Cleaning 13 8 1 2 Safety valve verification 13 8 1 3 Safety valve 13 8 1 4 Maintenance and repair 13 8 ...

Page 3: ...e the appliance from the power supply Installation and conversion Only permit an authorised service to install this appliance Neverobstructthesafetyvalveoutlet During the heat up water may be expelled from the safety valve Maintenance Only authorised technicians are permitted to service this appliance Isolate the appliance from its power supply before commencing any maintenance work on the applian...

Page 4: ...nts apply in accordancewithEN60335 1inorderto prevent hazards from occurring when using electrical appliances This appliance can be used by children of8yearsandolder aswellasbypeople with reduced physical sensory or mental capabilities or lacking in experience and knowledge if they are supervised and have been given instruction in the safe use of the appliance and understand the resulting dangers ...

Page 5: ...lting from such use 2 2 Anticorrosion protection The inside of the tank is lined with homogeneous glass enamel completely neutral with regards to compatibility and contact with potable water This lining is neutral with regard to the use with potable water The existence of a magnesium anode provides additional anticorrosion protection 2 3 Accessories included in the appliance packaging Fig 1 1 Hook...

Page 6: ...city l 10 15 Weight empty kg 7 7 9 4 Weight when full kg 17 7 24 4 Water details Maximum permissible pressure bar 8 Water connections Pol 1 2 Electrical characteristics Nominal power W 1500 1500 Heating time T 50 C 0 h 23 min 0 h 35 min Voltage VAC 230 Frequency Hz 50 Monophasic electric current A 6 5 6 5 Power cable with plug HO5VV F 3 x 1 5 mm2 Protection class I Type of protection IPX4 Water te...

Page 7: ...nsions TR2000T 6 720 885 113 2018 04 2 5 Dimensions Fig 2 Dimensions in mm Fig 3 Appliance A B C D TR2000T 10 406 372 100 257 TR2000T 15 406 372 100 324 Table 4 A C 6720821791 02 1V G1 2 G1 2 B D min 96 mm max 114 mm 8 mm 6720810908 03 1V ...

Page 8: ...out CFC 3 Heating element 4 Hot water outlet male 5 Cold water inlet male 6 Magnesium anode 7 Thermal cut out 8 Thermostat 2 7 Electrical wiring diagram Fig 5 Electric circuit diagram 3 Regulations The country s regulations currentlyin forcemust be fulfilled for the installation of the electric appliances 1 2 7 6 3 4 5 6720821791 01 V 2 8 ...

Page 9: ... necessary maintenance procedures Protection areas 1 and2 Do not install in protection areas 1 and 2 Install the appliance outside the protection areas at a distance greater than 60 cm of the bath Fig 6 Protection areas Installation power connection and commissioning must only be carried out by a service approved for such work by the local entities CAUTION Do not drop the appliance Remove the appl...

Page 10: ...draulic connection to the appliance Fig 9 Water connection CAUTION Damage to appliance connections through contact corrosion Use galvanized insulators in your water connections These will avoid galvanic electric currents between the hydraulic link metals and consequently corrosion of these NOTICE Material damage Install a filter at the water inlet in areas where the water contains particles or sed...

Page 11: ...ndling Inordertoavoidproblemscausedbysudden pressure changes we recommend the installation of a non return valve at the appliance DANGER Install a safety valve at the water inlet of the appliance Fig 9 and 10 NOTICE NEVER OBSTRUCT THE PURGE OUTLET OF THE SAFETY VALVE Never install any accessory between the safety valve and the cold water inlet right hands side of the appliance 6720821785 04 1V If ...

Page 12: ... hot water tap Open the safety valve Fig 12 Wait until the appliance is completely empty Fig 12 Manual activation of the safety valve CAUTION Thefirststart upoftheappliance must be carried out by an authorized technician which will provide the user with all the necessary information to the best working and handling of the device Once the water has reached the selected temperature level the applian...

Page 13: ... you should use the return and collection systems put in place in the country concerned 8 Inspection Maintenance 8 1 User information 8 1 1 Cleaning Never use abrasive corrosive or solvent cleaning detergents Use a soft cloth to clean the exterior of the appliance 8 1 2 Safety valve verification Verify that the water is expelled during the heating process through the safety purge valve Never obstr...

Page 14: ...e 2 Verifythemagnesiumanode 3 andreplaceitifnecessary CAUTION Damages to the glass enamel Never clean the enamel interior of the appliance with decalcifying agents The magnesium anode ensures anti corrosion protection There is no need for alternative products for the protection of the enamel This appliance disposes of an anti corrosion magnesium anode in the inside WARNING It is forbidden to opera...

Page 15: ...t from all the hot water taps Turn on the appliance to the electric current 8 3 Safety thermostat The appliance is equipped with an automatic safety thermostat If for any reason the water temperature inside the appliance exceeds the safety limit the switch will trigger and cut all electric current supplying the appliance thus avoiding any accidents 8 4 Requiredactionsafteranymaintenancework has be...

Page 16: ... the device X X Incorrecttemperatureregulatingthrough the thermostat Regulate the thermostat X Thermostat temperature safety active Replace or re install the thermostat X Damaged heating element Replace the heating element X Incorrect functioning of the thermostat Replace or re install the thermostat X X X Device incrustation and or from the safety group Perform a descaling of the appliance If nec...

Page 17: ...17 TR2000T 6 720 885 113 2018 04 Notes ...

Page 18: ...18 TR2000T 6 720 885 113 2018 04 Notes ...

Page 19: ...19 TR2000T 6 720 885 113 2018 04 Notes ...

Page 20: ...n Street Ikeja GRA Lagos Nigeria Tel 234 908 781 4939 ROBERT BOSCH EAST AFRICA LTD 4th floor Fedha Plaza P o Box 856 00506 Westlands Nairobi Kenya Tel 254 74 2967640 254 70 0651436 Fax 254 20 3673231 ROBERT BOSCH LIMITADA Largo 17 de Setembro n 3 Presidente Business Center 4 Andar Escritorio 429 Luanda Angola ROBERT BOSCH PTY LTD 15th Road Randjiespark 1685 Midrand South Africa Tel 011 651 9600 Fa...