background image

 

 

Parking Lot Sensor TPS110 EU 

1 | 14 

 
 

 

Parking Lot Sensor TPS110 EU 
User manual 

Summary of Contents for TPS110 EU

Page 1: ...Parking Lot Sensor TPS110 EU 1 14 Parking Lot Sensor TPS110 EU User manual ...

Page 2: ...ot sensor 4 Preparation of the parking space 4 Installation of the sensor base 6 Installing the sensor 8 Replacing removing the BOSCH Parking Lot Sensor 9 Setup and operation of the parking lot sensor in the backend 11 Technical specifications 11 Legal information 12 Disposal note in accordance with ElektroG and WEEE Directive 2012 19 EU 12 EU Declaration of Conformity 12 Note for transport 12 OSS...

Page 3: ...nd connection The backend as well as the associated management software must be functional Make sure that all ofl the required components see Fig 1 TPS110 EU sensor as well as the tools are ready Figure 1 TPS110 EU Sensor 2 Installing the sensor base The sensor base is attached to the substrate e g concrete asphalt To do this we recommend a two component adhesive The adhesive is available in vario...

Page 4: ... sensor 10 T20 screw 11 Sensor cap sensor sealing cap Preparation of the parking space The parking space must be free of dirt dust oil water and other contaminants For this purpose at least one swept area should be prepared However it is recommended to clean the surface to remove contamination using a high pressure cleaner and a burner The installation must take place in the center of the parking ...

Page 5: ...for sensor installation This is crucial for the contact surface and the adhesive effect of the sensor Figure 5 Substrate example continuous Figure 6 Substrate example gap INFORMATION For the bonding procedure please follow the instructions of the adhesive manufacturer e g temperature safety information and work instructions A parking space cleaning should be clarified in advance with the parking l...

Page 6: ...rtridge here bayonet fitting Figure 7 Inserting the cartridge Figure 8 Sealing cap Figure 9 Mixing tube To avoid contamination and to get the maximum use out of the plasma cleaning process open the sensor base package just before applying the adhesive Apply about 40 ml of the DELO PUR 9692 adhesive in the center see Fig 10 Adhesive application and Fig 11 Adhesive amount If you use a 50 ml cartridg...

Page 7: ...ying light pressure on the sensor base see Fig 12 Sensor base attachment Make sure that the sensor is centered in the parking space and that the Bosch logo on the sensor base points towards the access road see Figure 13 Sensor base installed Subsequent twisting of the sensor base is not possible INFORMATION Once the adhesive in the mixing tube has cured it cannot be used again At room temperature ...

Page 8: ...e sensor and damage it The functionality of the parking lot sensor is not guaranteed if it is installed incorrectly Make sure that the sealing rings on the cap and sensor are seated correctly Do not install the sensors when it is raining Do not use damaged components Do not open the sensor housing Only use original replacement parts Warning Risk of explosion Extreme heat can damage the battery and...

Page 9: ...h the sensor sealing cap Figure 14 Installing screwing in the sensor After the installation of the sensor the sensor learns about parking changes which happens in its vicinity After approx 10 parking changes the sensor is in its taught in state 2 Replacing removing the BOSCH Parking Lot Sensor T o r e place the parking lot sensor only the sensor needs to be replaced To do this remove the sensor ca...

Page 10: ... remove the sensor base from the parking space it is necessary to use a hammer and chisel to destroy the adhesive effect by chiseling the sensor base parallel to the parking space surface As a result there is no permanent damage to the parking space ...

Page 11: ...nsor can be found on our website at https www bosch connectivity com parking lot sensor downloads 12 Technical specifications Table 1 Device specifications Additional information can be found in the datasheet on the website at https www bosch connectivity com parking lot sensor downloads PROPERTIES VALUES Temperature range 30 C to 65 C Humidity 0 97 Protection class IP67 IPx9K Dimensions 145 4 mm ...

Page 12: ...eclares that the Parking Lot Sensor TPS110 EU radio system type is in compliance with Directive 2014 53 EU Radio Equipment Directive and Directive 2011 65 EU RoHS Directive The full text of the EU Declaration of Conformity is available at the following web address https www bosch connectivity com parking lot sensor downloads 3 Note for transport The TPS110 EU contains a lithium metal battery and i...

Page 13: ...Note that this document cannot contain complete and up to date information on all the requirements to be observed The consignor is responsible for fulfilling all the requirements for the transport of lithium batteries themselves The International Air Transportation Association IATA has issued further regulations on the transport of lithium batteries IATA International Air Transport Association Lit...

Page 14: ...Parking Lot Sensor TPS110 EU 14 14 Bosch Connected Devices and Solutions GmbH BCDS Ludwig Erhard Straße 2 72760 Reutlingen Germany support bosch connectivity com ...