Technical Data
Table 4
Technical Data
Symbol
Units
T4200 11-2D
T4200 14-2D
T4200 18-2D
Output and heat demand
Rated max. heat output
Pn
kW
(Btu/h)
19,2
(65570)
23,6
(80595)
30,5
(104165)
Rated min. heat output
Pmin
kW
(Btu/h)
7,0
(23905)
9,0
(30710)
9,3
(31733)
Output (modulation range)
kW
(Btu/h)
7 - 19,2
(23905-65570)
9,0 - 23,6
(30710-80595)
9,3 - 30,5
(31733-104165)
Rated max. heat input
Qn
kW
(Btu/h)
21,8
(74450)
27,0
(92210)
34,5
(117825)
Rated min. heat input
Qmin
kW
(Btu/h)
9,5
(32415)
10,4
(35486)
10,8
(36851)
Gas supply specifications
1)
1) Hi 15 °C - 1013 mbar - dry: Natural gas 34.2 MJ/m
3
(9.5 kWh/m
3
)
LPG: Butane 45.72 MJ/kg (12.7 kWh/kg) - Propane 46.44 MJ/kg (12.9 kWh/kg)
Supply pressure
Natural gas H
G20
kPa
2,0
2,0
2,0
LPG (butane/propane)
G30/G31
kPa
2,8
2,8
2,8
Consumption
Natural gas H
G20
m
3
/h
2,2
2,77
3,5
LPG (butane/propane)
G30/G31
kg/h
1,75
2,2
2,79
Number of injectors
12
14
18
Water system specifications
Max. water pressure
2)
2) Considering the water dilution effect this value must not be exceeded
pw
MPa
1,2
1,2
1,2
Temperature control at maximum setting
Temperature increase
°C
50
50
50
Flow range
l/min
2 - 5,5
2 - 7
2 - 8,8
Min. operating pressure
pw
min
MPa
0,01
0,01
0,02
Minimum pressure for maximum flow
MPa
0,025
0,035
0,05
Temperature control at minimum setting
Temperature increase
°C
25
25
25
Flow range
l/min
4 - 11
4 - 14
4 - 17,6
Min. operating pressure
MPa
0,02
0,02
0,02
Minimum pressure for maximum flow
MPa
0,06
0,1
0,13
Flue specifications
3)
3) For nominal calorific power
Draught requirement
MPa
0,0015
0,0015
0,0015
Flow rate
g/s
13
17
22
Temperature
°C
160
170
180