4.10 Water softening system
Unscrew the outside door, the base panel, the angle strip and the side
panels; unfasten the tension cords on the hinge levers; unscrew the
screws which connect the base pan to the hinge plates; unscrew the
rinsing tank from the rear panel of the base pan; separate the door
cable harness on the plug-and-socket connection in the base pan;
remove the electrical connections from the regeneration and drainage
valve; unscrew the nut which connects the salt dispenser to the
rinsing tank; draw saline solution out of the dispenser with a suction
syringe; place the appliance on its back; carefully remove the base
pan and release the catch on the level sensor housing and the water
softening system; separate the circulation pump with the rubber
support from the base pan; remove the base pan until the water
softening system can be pulled off the plug-and-socket connections
on the water inlet and the level sensor housing; pull out the reed
switch;
Note:
1.
The following work must be carried out before the water
softening system is installed:
2.
Place the seal on the filler neck of the salt dispenser.
3.
Insert sealing rings into the plug-and-socket connections.
4.
Put rubber cap on the bearing support in the base pan for the
pump sump.
5.
Insert the switch rod for actuation of the safety level switch.
6.
Fit the rubber bearing to the circulation pump.
Salt container:
Capacity:
Finely ground salt approx. 1.3 kg
Rough-grained salt approx. 0.9 kg
58300000002393_ara_en_a.doc – 31.07.07