3.10 Programme
reset
When the appliance is switched on, simultaneously press the S2 and
the S4 buttons for 3 sec. The appliance is drained for approx. one
minute. Then close the detergent dispenser to reset the dispenser.
3.11 Special
functions
3.11.1 Setting the hardness range
Hold down the S3 button and switch on the appliance. The low salt
LED flashes. The programme LEDs display the set value (see table).
The set value increases by one each time the S3 button is pressed.
If the appliance is switched off, the value is saved.
°dH
°fH
°Clarke
mmol/l
LEDs
L2
L3
L4
0
0–6
0–11
0–8
0–1.1
{
{
{
1
7–16
12–29
9–20
1.2–2.9
{
{
2
17–21
30–37
21–26
3.0–3.7
{
3
22–35
38–60
27–44
3.8–6.2
Standard setting = 2
3.12 General information on control
3.12.1 Tap turned off
The appliance stops in the programme 6 minutes after the start of
programme (scan filling position). The selected programme LED is
permanently lit on the control. The control remains in this position until
the filling level has been reached.
3.12.2 Regeneration electronics (optional)
The electronics determine, in comparison with the water hardness set
on the appliance, the volume of water which is possible until the
softening system is exhausted.
The volume of water which has run through is calculated.
Regeneration then takes place once the maximum possible number of
rinse cycles has been reached.
The sequence characteristics of the regeneration electronics are
described under Initial start-up / Replacing the electronics.
General information:
If the new control is used on appliances with a mechanical hardness
range setting (setting on the salt dispenser), the hardness range on
the electronics module must be set to the highest setting range. The
hardness range is still set mechanically.
3.12.3 Warm
water
detection
If the water running in for the final rinse is hotter than 45 °C, the heat
exchanger for the drying phase is not filled. In order to ensure the
temperature difference required for condensation, the temperature in
the final rinse cycle is increased to 72 °C, thereby increasing the
inherent heat of the dishes.
3.12.4 Setting the buzzer (as from FD8012)
When the door is opened, simultaneously press the S3 button and the
main switch. The LED above button S3 flashes. The buzzer can be
activated or de-activated by pressing button S3. The setting is saved
by switching off the appliance.
58300000002393_ara_en_a.doc – 31.07.07
Seite 15 von 60