Master Code Functions
Master Code Functions are designed to allow those users that have the appropriate access level to perform certain functions
of a supervisory level. These functions can only be carried out when the system is disarmed.
+
+
Function
Description
0
Arming and Disarming Both Areas At The Same Time
1
Changing and Deleting User Codes/Remote Radio User Codes
2
Changing Domestic Phone Numbers
3
Event Memory Recall Mode
4
Walk Test Mode
5
Fault Analysis Mode
6
Setting The Date and Time
7
Turning Day Alarm On and Off
8
Reset Latched Outputs
9
Initiate A Modem Call
Master Code Functions
Fault Analysis Mode
There are various system faults that can be detected by the control panel. When any of these are present the
FAULT
indicator will begin to flash and the codepad will beep once every minute. Hold the
5
button down for two seconds until
two beeps are heard. The
STAY
and
AWAY
indicators will begin to flash in unison with the
FAULT
indicator. One or more
zone indicators (1-8) will illuminate to indicate the system fault. Refer to the following table for the list of different system
faults that may occur.
Zone
Indicator
Description
1
Low Battery
2
Date and Time
3
Sensor Watch
4
Horn Speaker Monitor
5
Reserved
6
E
2
Fault
7
Zone Transmitter Low Battery
8
Communications Failure
Fault Types
User Code Functions
+
+
Function
Description
0
Arming and Disarming Both Areas At The Same Time
Solution 6+6 Wireless - AE
Quick Reference Guide
ISSUE 1.00
Bosch Security Systems Pty Limited
Page 7
Summary of Contents for Solution 6+6 Wireless AE