Item
Location
Option
Default New
Partitioning Options 1
0500
1 = First to Disarm/Last to Arm reporting
2 = Reserved
4 = Reset sirens from any area allowed
8 = Reserved
0
Partitioning Options 2
Item
Location
Option
Default New
Partitioning Options 2
0501
1 = Reserved
2 = User codes allowed to arm/disarm both
areas at same time (Code [0][#])
4 = Reserved
8 = Reserved
0
Partition Allocations
Zone Area Assignment
Item
Location
Default
New
Item
Location
Default
New
Zone 1 Area
0502
1
Zone 2 Area
0503
1
Zone 3 Area
0504
1
Zone 4 Area
0505
1
Zone 5 Area
0506
1
Zone 6 Area
0507
1
Zone 7 Area
0508
1
Zone 8 Area
0509
1
Zone 9 Area
0510
1
Zone 10 Area
0511
1
Zone 11 Area
0512
1
Zone 12 Area
0513
1
Zone 13 Area
0514
1
Zone 14 Area
0515
1
Zone 15 Area
0516
1
Zone 16 Area
0517
1
Option
0 = Zone area not assigned
1 = Zone assigned to Area 1
2 = Zone assigned to Area 2
3 = Zone assigned to both Area 1 and Area 2
Notice!
Solution 2000 supports zone 1 – 8 only.
4.15.8
4.15.9
4.16
4.16.1
Control Panel
Programming Parameters | en
43
Bosch Security Systems, Inc.
Quick Reference Guide
2015.06 | 03 | F.01U.298.027