System Status Programming
Access Denied(Code Retry)
Item
Location
Option
Default New
Code retry limit
0424
0 = Unlimited
1 – 15 = Error code attempts
6
System Status Reporting Options
Item
Location
Option
Default New
System Status
Reporting Options
0427
0 = No report required
1 = Report to Receiver 1
2 = Report to Receiver 2
4 = Report to both Receiver 1 and Receiver 2
8 = Report to Receiver 2 only if Receiver 1
fails
1
Test Report Programming
Test Report Time (Automatic)
Item
Location
Option
Default New
Hour of day (tens digit)
0428
0
Hour of day (units digit)
0429
0
Minute of day (tens digit)
0430
0
Minute of day (units digit)
0431
0
Repeat interval in days
0434
0 = Disable
1 – 15 = 1 – 15 days
0
Test Reporting Options
Item
Location
Option
Default New
Test Reporting Options 0435
0 = No report required
1 = Report to Receiver 1
2 = Report to Receiver 2
4 = Report to both Receiver 1 and Receiver 2
8 = Report to Receiver 2 only if Receiver 1
fails
1
4.11
4.11.1
4.11.2
4.12
4.12.1
4.12.2
Control Panel
Programming Parameters | en
33
Bosch Security Systems, Inc.
Quick Reference Guide
2015.06 | 03 | F.01U.298.027