4.1.3.3
Softer bearing (UC/11 and later)
Softer bearing (UC/11 and later) & non-softer bearing (UC/06)
heater assemblies, circulation pumps and sumps
cannot
be
mixed and matched. Softer bearing heaters don’t fit in older
models and older heaters don’t fit in softer bearing models.
Softer bearing & non-softer bearing heater assemblies are
connected to circulation pumps differently:
•
Softer bearing models (UC/11 & above) have gasket
assembled to heater and have a separate hose clamp
(order #
172272
).
•
Older models (UC/06) have a separate gasket and do
not have a hose clamp.
4.1.3.4
Top Rack Only
Models with
Top Rack Only
have separate actuators mounted
underneath heater assemblies. The actuator moves a magnetic
float to block the lower rack port, diverting water to the top rack.
Lower
spray arm
Lower spray arm
Magnetic
float
Magnetic float
Magnet
Magnet
The actuator moves a magnet under the magnetic float so the
north poles align, repelling the magnetic float upward until it
blocks the water flow to the lower spray arm.
Actuator (hot
wax motor)
Actuator (hot
wax motor)
Heater with top rack housing
Both racks
702_58300000148618_ara_en_a
Page 11 of 42
Top rack only