Prerequisites for Commissioning
2–7
1070 066 037-101 (00.02) GB
Reinitializing DSS after module RESET or a module change
If, while DSS is running, you
disconnect the connection cable from the inverter (e.g. for starting up a
new drive), or
press the RESET key of the currently connected inverter,
you then have to re-initialize the DSS. This is the only way to ensure that the
DSS does not work with invalid or outdated data.
CAUTION
Uncontrolled motor movements are possible!
For as long as the drive is enabled, you must neither press the
”Reset” key nor disconnect the cable between the DSS and the drive.
First stop the movement and disable the drive.
Initiate the ”Initialize module type” command:
menu sequence
CONTROL
RESET
INIT. MODULE TYPE,
-or-
click on
in the icon bar.