Bosch Security Systems | 3/04 | 4998132005B
EN |
2
RF3503E
| User Guide | 1.0 Overview
4.0
Installing and Changing the
Battery
1.
Remove the two screws used to attach the belt clip
(if used) to the transmitter.
2. Remove the battery cover screw.
3. Remove the battery cover.
4. Install the battery, observing polarity.
1.0
Overview
The RF3503E is a wireless, two-button transmitter that
sends a medical or panic alarm signal to your
monitoring system. Each RF3503E is programmed with
a unique code that allows your monitoring system to
recognize individual transmitters.
Although the range of the transmitter can be up to
100 m in open air, typical building materials can greatly
reduce the range of your unit. It is recommended that
you try out your transmitter at various locations in the
monitored area to test the range.
2.0
Specifications
Table 1: Specifications
Battery
Voltage
3 VDC
Recommended
Battery Types
Duracell DLCR2
Eveready EL1CR2
Sanyo CR2
Battery Life
Approximately 5 years under normal
use with recommended battery
types.
Operating
Temperature/
Humidity
-20°C to +65°C
0% to 95% relative humidity
(non-condensing)
Length
10.5 cm
Width
4.0 cm
Depth
2.1 cm
Weight
85 g
Frequency
433.42 MHz
Compatible
Receivers
RF3227E
RF3249E
3.0
Selecting the Receiver
1.
Install the jumper to use with the RF3249E Receiver.
2. Remove the jumper to use with the RF3227E
Receiver.