RE 30523-B/09.13 | Installation and operation
Hydraulics
| Bosch Rexroth AG
37/48
Operating the VSPD 4
To exit Configuration Mode
As an example, the second level of the “Setup” menu is shown.
The display on the controller card shows the option “Sprache/Language“.
¾
Press
“ESCAPE”.
9
The display is scrolling “Setup“.
¾
Press
“ESCAPE”.
9
The display will show scrolling text to display the manufacturer’s name, the soft-
ware version for the controller, or a custom configured text string
If while in Configuration Mode no entry is made within one minute, the
controller card will automatically return to successively higher menu
levels until Run Mode is reached.
The VSPD Control Card is fully operational in Configuration Mode.
To change a parameter using the input keys
As an example, the parameter "Max. Value" (see Fig. 13 Menu tree „Analog I/O Part
1“–Inputs – AI1) is shown. In this case, set the parameter to: “+10 Volts“.
The card is now in Run Mode.
The display will show scrolling text to display the manufacturer’s name, the software
version for the controller, or a custom configured text string.
______________________________________________________________
WARNING!
When changing parameters using the input keys, hardware inputs
are configured even when the discrete input “Enable” is active.
Caution:
Do not change
any analog input from voltage to current or current
to voltage when active.
Changing the analog inputs configuration may result in incorrectly
interpreted values.
This can result in uncontrolled system operation and damage
to the machine!!
______________________________________________________________