RE 30523-B/09.13 | Installation and operation
Hydraulics
| Bosch Rexroth AG
35/48
Operating the VSPD 4
4.4 Display/Input Key Operations (Option Display)
All operations can be performed directly on the card using the "UP", "DOWN", "EN-
TER" and "ESCAPE" keys.
The keys are especially useful for quickly and easily checking, changing
or correcting parameters and settings.
Always use BODAC software for the initial startup before placing the card
in service.
Before making any changes to parameters or settings, familiarize yourself with the
menu structure of the card. This can be found in section 4.3: "Menu tree for settings
and parameters".
Key functions:
Pressing the "UP" key moves in the upward direction, within the selected level, to
available menu items. (for an overview, see section 4.3 Menu Tree for Setup and
Parameters)
Pressing the "DOWN" key moves in the downward direction, within the selected level,
to available menu items (for an overview, see section 4.3 Menu Tree for Setup and
Parameters).
Change menu mode:
Parameterization Menu
Press the "ENTER" key for 2 seconds or longer, to switch to configuration mode –
"EDIT Parameters".
Change menu level:
Press the “ENTER“ key to take you one level lower in the menu structure, or confirms
an entered value.
Note: The entered value will be stored in memory by returning to level 0 (dis-
playing the manufacturer’s name).
The process of storing the data will take about a minute. During this time do not
cut off the current supply of the card, otherwise your changes won’t be saved in
the memory.
Pressing the "ESCAPE" key takes you one level higher in the menu structure.
Configuration Menu:
Pressing the “ENTER“ and “ESCAPE“ keys simultaneously opens the configuration
menu.
The configuration menu is structured in levels. The first level contains main catego-
ries, below which are additional sub-categories and settings. Depending on the entry
selected, a main category may have up to 4 sub-levels.