Signal specification
Signal
Specification
+5V
Repeater supply
+5 V (±10%)
Max. 75 mA
Repeater control signal
TTL-compatible:
●
1: Transmit
●
0: Receive
Output resistance: 350R
V
OL
≤ 0.8 V at I
OL
≤ 2 mA
V
OH
≥ 3.5 V at I
OH
≤ 1 mA
Receive/transmit data
EIA-RS485 standard
Tab. 7-21:
Signal specification
Danger of destroying output
"+5V repeater supply" by overload!
NOTICE
Do not short-circuit the output.
Do not exceed the maximum current.
Bus connectors
The PROFIBUS connectors each have a connectable terminating resistor.
The terminating resistor must always be active at both the first and last bus
node. Carry out the connection as shown in the figures below.
1)
Shield
2)
Bus connection and switch position for first node and last node
3)
Bus connection and switch position for all other nodes
Fig. 7-11:
Preparing a cable for connecting a bus connector
To assemble the bus cable, proceed as follows:
●
Use cable according to DIN EN50170 / 2 edition 1996
●
Strip cable (see figure above)
●
Insert both cores into screw terminal block