5 Initial Start Up
After the electric hydraulic system has been correctly assembled, users can take
following steps for initial start up.
1. Select pressure sensor via F2.10 (for option ''0: Others", please set F2.06,
F2.07 manually).
2. Choose motor parameter via F1.15 and F1.16 for Rexroth MOT-FC_HOY mo-
tor. For other motors set F1.15 to 0, and set motor parameter in EFC pa-
rameter group C, please reference EFC 5610 quick start guide (material
number is R912005856).
3. Set pressure command via F1.03...F1.08 and flow command via
F1.11...F1.14.
4. Run the FcP system.
●
The pressure command F1.05 and flow command F1.12 default
values are set to low values to prevent potential machine damage
caused by improper use during initial start up.
●
For CytroPac application, set F1.20 according to different Cytro-
Pac type.
Code
Name
Setting range
Default Min.
Attri.
F1.03 Pressure command source
0: Depend on the value of F1.04
1: Select by digital input (F1.04
shows status)
2: Analog input
3: Communication
0
-
Stop
F1.04 Pressure command selection
0: Pressure command digital set-
ting 0
1: Pressure command digital set-
ting 1
2: Pressure command digital set-
ting 2
3: Pressure command digital set-
ting 3
0
-
Run
F1.05 Pressure command digital set-
ting 0
0.0...1,000.0 bar
10.0
0.1
Run
F1.06 Pressure command digital set-
ting 1
0.0...1,000.0 bar
10.0
0.1
Run
F1.07 Pressure command digital set-
ting 2
0.0...1,000.0 bar
10.0
0.1
Run
F1.08 Pressure command digital set-
ting 3
0.0...1,000.0 bar
10.0
0.1
Run
FcP 5020
Bosch Rexroth AG
Initial Start Up
DOK-RCON03-FCP5020****-QU04-EN-P