Power switch
Fig. 8: Power switch
On the SB356, the trigger behavior of the Q0
power switch must be assigned as follows:
Mains connected loads
(nominal values)
The required connected load of the SB356
system box depends on the number and size
of the tightening channels to be operated. As,
however, an SB356 must always be
considered as fully equipped, we
recommend configuring the connected load
for a fully equipped SB356 system box (see
chapter “15 Technical data”).
If the SB356 system box is not fully equipped
and fused and it is certain that they will not be
retrofitted with additional tightening
channels, the mains connected load can be
configured in accordance with Table 4.
Table 3:Trigger behavior of power switch
Voltage
Power setting on Q0
380 V
Group 1
(G1)
5.0 A
400 V
4.8 A
420 V
4.5 A
440 V
Group 2
(G2)
4.3 A
460 V
4.1 A
480 V
4.0 A
500 V
Group 3
(G3)
3.8 A
Setting
mark
5 A max
Tab. 4:3-phase connection
Number of LT35x in SB356
1*
2
3
4
5
6
LT353
with
EC302
500
VA
700
VA
900
VA
1050
VA
1200
VA
1350
VA
LT353
with
EC303
600
VA
950
VA
1250
VA
1500
VA
1750
VA
2000
VA
LT354
with
EC304
700
VA
1200
VA
1700
VA
2100
VA
2500
VA
–
LT355
with
EC305
1200
VA
1800
VA
2500
VA
–
–
–