Danger due to permanent magnets!
WARNING
Health hazard for persons with heart pacemakers, metallic implants
and hearing aids in direct environment of permanent magnets.
Crushing hazard of fingers and hand due to heavy attractive forces
of the magnets.
Risk of destruction of sensitive parts such as watches, credit
cards, ... .
The permanent magnets on the rotor must be demagnetized before
disposal to avoid injuries or damage.
Dismagnetize magnets
The dismagnetization of the magnets on the rotor is reached via a special ther-
mal handling. The handling duration is influenced by the frame size of the rotor.
The rotor must remain for 30 minutes in the oven, starting at the time, the mag-
netic surface has reached 300 °C. If the magnets are surrounded by a bandage,
we recommend to remove them before heating-up the rotor in an oven to unfold
the magnets.
In the case of successful demagnetization, the magnets can be sepa-
rated from the rotor sleeves after cooling of the rotor without any
effort.
Packaging
Out packaging materials do not contain any problematic materials and can be re-
cycled without any problems. Wood, cardboard and styrofoam are used as pack-
aging materials.
Batteries and Accumulators
Batteries and accumulators can be labeled with this symbol.
The symbol indicating "separate collection" for all batteries and accu-
mulators is the crossed-out wheeled bin.
End users in the EU are legally bound to return used batteries. Outside the valid-
ity of the EU Directive 2006/66/EC, the particularly applicable regulations must
be followed.