53 / 72
MS2N
Electrical connection
Bosch Rexroth AG
R911347581, Edition 05
3.
Turn the nut clockwise (arrow direction
“close”)
Tightening torque hand-tight or 1.5 Nm.
At a minimum, the lock must be turned by
approx. 20° (at least 3 clicks), or until the
marking a is in the area b.
🡆
Should this position be reached, the
connector is safely locked.
4.
Secure the cables, that accruing forces
due to cable vibrations onto the connector
are prevented.
Disconnect SpeedTec connector
1.
Turn the nut counterclockwise (arrow
direction “open”)
2.
Straight and evenly disconnect the con-
nector from the mounting box.
🡆
The plug is disconnected.
7.4.18 Plug-in connector with
threaded connection
WARNING
Risk of personal injury or damage to property
due to disconnecting or connecting live plug con-
nections!
−
Only disconnect or connect plug connec-
tions when they are dry and de-energized.
−
During operation of the system, all plug con-
nections must be firmly locked or screwed
tight.
Observe when connecting the flange sockets:
•
Protect the device connectors from external
force effect.
•
Connect the motor to ready-made connec-
tion cables.
Connect the plug-in connector with the
threaded connector M58
Before connecting, please ensure properly meas-
ured ready-made connection cables are available.
The type, size and cable cross section of the
plug-in connector must be adjusted to the motor.
As
sembl
y