24
/54
Control blocks for mobile applications
| Transport and storage
Bosch Rexroth AG, RE 64025-B/2021-08-12
If a removed control block is to be stored, it must be preserved against corrosion
for the duration of storage.
The following instructions only refer to control blocks which are operated with
a hydraulic fluid on a mineral oil basis. Other hydraulic fluids require other
specific preservation measures. In this case, please contact Bosch Rexroth.
For the address, see chapter 10.5 "Spare parts" on page 42.
Bosch Rexroth recommends the following procedure:
1�
Clean the control block.
2�
Drain the control block.
3�
Plug all ports so they are airproof.
4�
Moisten the unpainted flange surfaces and external seals of the control block
with mineral oil.
5�
Protect sensitive assembled parts (e.g. actuation elements, sensors, solenoids
or valves) with appropriate measures as in the delivery state.
6�
Package the control block with a suitable desiccant in corrosion protection film
so that it is airproof.
7�
Store the control block in a non-explosive area protected against collisions, see
the Section entitled "Requirements" on page 23 in this chapter.
8�
If necessary, return the control block for repair to Bosch Rexroth-Service.
After removal