5.4.2
KCU02 data sheet
KCU data sheet - Currents, voltages, power
Description
Symbol
Unit
KCU02.2N-ET-ET*-025-NN-N-NN-NW
Listing in accordance with UL
standard
UL 508C
Listing in accordance with CSA
standard
C22.2 No. 274-13
UL files
E134201
Mass
m
kg
3.80
Degree of protection according to
IEC60529
IP20
Minimum distance on the top of
the device
1)
d
top
mm
80
Minimum distance on the bottom
of the device
2)
d
bot
mm
110
Horizontal spacing at the device
3)
d
hor
mm
0
Temperature
increase
with
minimum distances d
bot
; d
top
; P
BD
ΔT
K
< 60
Cooling type
Forced
Volumetric capacity of forced
cooling
V
m
3
/h
approx. 0.3
Power dissipation at continuous
current and continuous DC bus
power respectively
P
Diss_cont
W
90
Insulation resistance at 500 V DC
R
is
Mohm
> 50
Average sound pressure level
(accuracy class 2) at P
DC_cont
4)
L
P
dB (A)
< 70
Control voltage data - input
Control voltage input
5)
U
N3
V
DC 24 ±20 %
Rated power consumption control
voltage input at U
N3
P
N3
W
675
Max. inrush current at 24 V supply I
EIN3_max
A
10.00
Pulse width of I
EIN3
t
EIN3Lade
ms
< 1000
Input capacitance
C
N3
mF
11.00
Maximum allowed voltage for
1 ms
U
N3_max
V
33.00
Control voltage data - output
Nominal voltage
U
out
V
42.0
Nominal power
P
out
W
588.0
Latest amendment: 2017-01-20*
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
87/407
Technical data of the components
R911335703_Edition 04 Bosch Rexroth AG