2
1
1
3
①
Fastening screws of the housing cov-
er (internal hexagon T10)
②
Fastening screws of the slot covers
(internal hexagon T10)
③
4 PCI/PCIe slots (depends on the PC
box type)
Fig. 10-5: Position of the housing cover and of the fastening screw for control cabinet
PCs with four slots
5. Remove the housing cover.
6. Remove the fastening screw (internal hexagon T10) of the slot cover and
the slot cover itself.
7. Insert the extension card and fix it using a fastening screw.
8. Mount the housing cover.
If the card is equipped with a Plug-and-Play (PnP) function, the card is
automatically detected by the operating system and integrated into the system,
provided that there are no hardware conflicts (IRQ etc.) with other extension
cards or connected devices.
There are the following causes if the functions of the new card are not available
after the system boot:
●
The card is not correctly positioned in the slot
●
The driver software of the card is not or incorrectly installed
IndraControl VPB 40.4
Bosch Rexroth AG
Mounting, demounting and electric installation
DOK-MLC***-INDRACTRLV4-IT02-EN-P
25/87
Summary of Contents for Rexroth IndraControl VPB 40.4
Page 1: ...IndraMotion MLC IndraControl VPB 40 4 Operating Instructions R911383090 Edition 02 ...
Page 88: ...Bosch Rexroth AG IndraControl VPB 40 4 82 87 DOK MLC INDRACTRLV4 IT02 EN P ...
Page 92: ...Bosch Rexroth AG IndraControl VPB 40 4 86 87 DOK MLC INDRACTRLV4 IT02 EN P ...
Page 93: ...Notes IndraControl VPB 40 4 Bosch Rexroth AG ...