7
Interfaces
S1
not
Off: Cable length ≤ 30 m
On: Cable length > 30 m
XVID
XSER
XUSB1/2 XUSB3/4 XUSBIN
X1S1
NC
GND 24V
+24V
used
Fig. 7-1:
Interface to the control cabinet PC with CDI interface
Fig. 7-2:
Interface to the control cabinet PC with CDI+ interface
Malfunctions due to insufficient shielding!
NOTICE
Use only shielded cables and metallic or conductive connector/coupling
covers with large-area shield support.
Material damages to electronics due to
missing functional earth!
NOTICE
Ensure that the functional earth is connected, because otherwise the
electronics can be destroyed by a potential difference between the
VDP 16.3/40.3/60.3 and the PC if the voltage supply is interrupted to only
one device and established again. A direct connection between the functional
earth and the VDP xx.3 and the VPB 40.3 and VSB 40.3 is recommended. If
the functional earth is wired at a neutral point, also connect the control
cabinet PC (VPB 40.3, VSB 40.3) to this neutral point.
7.1
Interfaces at the VDP
7.1.1
Overview
Name at
the
housing
Availability Connection type
Connector
type, integrated
Mating
connector or
cable (from
outside)
X1S1
At all
devices
24 V DC voltage supply Phönix
connector strip,
3-pin, MC1,5/3-
G-3,5 THT
Phönix socket
strip,
3-pin, FK-MCP
1,5/3-ST-3,5
XUSB1/2
At all
devices
2 USB interfaces
USB socket,
4-pin, type A
USB plug,
4-pin, type A
XUSB3/4
At all
devices
2 USB interfaces
USB socket,
4-pin, type A
USB plug,
4-pin, type A
IndraControl VDP 16.3, VDP 40.3, VDP 60.3 Operator Display
35/57
Interfaces
R911323862_Edition 07 Bosch Rexroth AG