7.8.2
Pin Assignment of the VAC 30.2 Connection Module
3
3
4
4
1
1
2
2
3
3
4
4
1
1
2
2
X1.1
X1.2
X2.2
X2.1
X3
Fig.7-19:
Connection module hand-held terminal
Pin
Signal name
X1.1 pin1
DC 24 V connection module VAC 30
X1.1 pin2
0 V
X1.1 pin3
DC 24 V hand-held terminal
X1.2 pin1
DC 24 V connection module VAC 30
X1.2 pin2
0 V
X1.2 pin3
DC 24 V hand-held terminal
X1.1 pin4
Terminal connected IN
X1.2 pin4
Terminal connected OUT
X2.1 pin1
STOP button 1 IN
X2.1 pin2
STOP button 1 OUT
X2.1 pin3
STOP button 2 IN
X2.1 pin4
STOP button 2 OUT
X2.2 pin1
Enabling button 1 IN
X2.2 pin2
Enabling button 1 OUT
X2.2 pin3
Enabling button 2 IN
X2.2 pin4
Enabling button 2 OUT
Fig.7-20:
Pin assignment of the connection module hand-held terminal
The connection module integrated in the VAM 11 and in the VAM 41 for a hand-
held terminal IndraControl VEH 30.1/30.2 or VCH 08.1 is also available as non-
integrated device with the name VAC 30.2.
The IndraControl VAC 30.2 connection module including automatic STOP but‐
ton jumpering is supplied with voltage via X1.1 pin1 or X1.2 pin1. The connected
hand-held terminal is supplied with voltage via X1.1 pin3 or X1.2 pin3. To make
the hand-held terminal engageable or disengageable when it is plugged-on, the
wire link between X1.2 pin1 and X1.2 pin3 is to be removed and the switching
voltage for the hand-held terminal is to be applied to X1.1 pin3 or X1.2 pin3.
DOK-SUPPL*-VAM*11/41**-PR03-EN-P
Rexroth IndraControl VAM 11.1/41.1 Machine Control Panels
Bosch Rexroth AG
57/83
Interfaces