Water quality specification
Pos.
Chemical element
Unit
Requirement
1
PH value
Range
7 … 8,5
2
Temporary hardness
°F
< 5,0
3
Total hardness
°F
< 10,0
4
Conductivity range
μS/cm
150 … 1000
5
Particle dimension
mm
0,02
6
Suspended particles
mg/l
< 0,2
7
Residue at 105°
mg/l
< 450
8
KMnO
4
consumption
mg/l
< 0,1
9
Ammonia
mg/l
< 0,1
10
Mineral oil
mg/l
< 0,1
11
Iron (Fe)
mg/l
< 0,5
12
Zinc (Zn)
mg/l
< 0,5
13
Manganese (Mn)
mg/l
< 0,2
14
Phosphor (P)
mg/l
< 1,0
15
Copper (Cu)
mg/l
< 0,2
16
Fluorides (F
-
)
mg/l
< 1,0
17
Nitrates (NO
3
-
)
mg/l
< 10,0
18
Free carbonic acid
mg/l
8 … 15
19
Oxygen (O)
mg/l
< 0,2
20
Alkalinity (CaCO
3
)
mg/l
< 200
21
Solphate ions (SO
4
2-
)
mg/l
< 100
22
Cloride ions (Cl
-
)
mg/l
< 50
Tab. 8-91:
Water quality specification (TIU_14_0003)
DOK-INDRV*-HXX05******-PR02-EN-P
Bosch Rexroth AG
295/407
Rexroth IndraDrive ML Drive Systems with HMU05
Cables, accessories, additional components