RE 15326-WA, Version 06.2020, Bosch Rexroth AB
Commissioning |
Hägglunds DUc Drive unit 57/88
Table 19: Oil volume in tank
Nominal level
Max level
Volume
Distance from top
Signal
Volume
Distance from top
Signal
Tank
model
litre
US
gallon
mm
in
mA
litre
US
gallon
mm
in
mA
130
130
34.3
85
3.35
16.9
137
36.1
53
2,09
18.7
220
220
58.1
95
3.74
17.5
234
61.8
50
1.97
19.2
300
300
79.2
80
3.15
18.0
318
84.0
39
1.54
19.6
350
350
92.4
125
4.92
16.3
385
101.7
57
2.24
19.0
400
400
105.7
87
3.43
17.8
425
112.3
49
1.93
19.3
600
600
158.6
82
3.23
18.0
625
165.1
44
1.73
19.5
700
700
184.9
83
3.27
18.8
715
188.9
60
2.36
19.3
900
900
237.8
83
3.27
18.8
915
241.7
60
2.36
19.3
Warning level
Alarm
(Stop) level
Volume
Distance from top
Signal
Volume
Distance from top
Signal
Tank
model
litre
US
gallon
mm
in
mA
litre
US
gallon
mm
in
mA
130
110
29.0
175
6.89
11.7
90
23.7
266
10.47
6.5
220
175
46.2
299
11.77
9.5
160
42.2
637
25.08
6.8
300
245
64.7
230
9.06
12.2
223
58.9
290
11.42
9.8
350
290
76.6
289
11.38
9.9
260
68.6
371
14.61
6.7
400
280
74.0
270
10.63
10.6
260
68.6
300
11.81
9.4
600
420
111.0
357
14.06
7.2
390
103.0
403
15.87
5.5
700
520
137.4
358
14.09
12.6
490
129.4
404
15.91
11.6
900
700
184.9
388
15.28
11.9
650
171.7
465
18.31
10.2
Point of
measure
Visual
level gauge
Fig. 53: Point of measure
DD00098816