RE 15326-WA, Version 06.2020, Bosch Rexroth AB
Installation |
Hägglunds DUc Drive unit 37/88
DD00102142
DD00102143
7.6 Hydraulic connections
During mounting of the hydraulic connections the following points must be
followed.
•
Do not remove coupling protections until final assembly.
•
Mount all external pipes to give sufficient working space to allow maintenance of
the Drive Unit.
• Always use hoses to connect with piping.
• All measures in the hydraulic system must be performed by professional service
personnel with knowledge of risks involved. Be especially accurate when
connecting the A- and B- connections (high pressure).
DANGER
Pressurized oil leakage
Danger to life or risk of injury.
▶ Do not open any connections if the hydraulic system is pressurized.
Fig. 23:
Connections DUc MS2, MT2
DD00102135
DD00102141
Fig. 24:
Connections DUc LS2, LT2