15.1.2 Recommended charge pressure
DANGER
Hanging load falls down!
Danger to life, risk of injury or damage to equipment, in hanging load applications!
▶
Charge pressure at motors connection must be according to recommended
pressure under all conditions, see
Fig. 22: Recommended charge pressure - CA
10 - CA 40 motors 2-port connection. Valid for oil viscosity 40 cSt
▶
Changes to the factory settings must only be made by Bosch Rexroth specialist
personnel.
The hydraulic system must be such that the motor will recieve sufficient charge
pressure at the low-pressure port. This applies to all types of installations.
There are two distinct cases:
The motor operating in braking mode
.
Required charge pressure at the inlet port is according to
.
The motor operating in driving mode only
For CAB 10 - CAB 40, 2-port or 4-port connected motors. The pressure at the low-
pressure port,
p
low
,
should , during operation of the motor, be at least one bar above
the case pressure,
p
case
. That is
p
low
=
p
case
+ 1 [bar], during operation.
p
low
=
p
case
+ 14.5 [psi], during operation.
NOTE!
The diagrams are valid for 1 bar (14.5 psi) case pressure. With increasing
case pressure the charge pressure must be increased accordingly. See
Recommended charge pressure - CA 10 - CA 40 motors 2-port connection. Valid