Assembly 31/48
RE29162-XE-B/10.20, DBET.../...XE,
Bosch Rexroth AG
Fig. 3: Cable and line entry
1
Clamping screw
2
Rubber seal
3
Hexagon socket head cap screws
4
Clampingbracket (strain relief)
5
Guide socket
6
Screw-in section
1.
De-energize and depressurize the relevant system part.
2.
Open the terminal box.
3.
Remove the outer sheath of the connection line and the insulation of the
individual conductors. Press the wire end ferrule on the individual conductors.
4.
Assemble the cable and line entries as shown in the drawing.
– Loosen the two hexagon socket head cap screws
(3)
of the clamping brackets
(4)
at the cable and line entry.
– Disassemble the clamping screw
(1)
, the rubber seal
(2)
and the guide socket
(5)
from the screw-in section
(6)
.
– Slide the clamping screw
(1)
and the rubber seal
(2)
with the guide socket
(5)
on the connection line. Guide them through the screw-in section
(6)
.
– Assemble the rubber seal
(2)
, the guide socket
(5)
and the clamping screw
(1)
on the screw-in section
(6).
Tighten the clamping screw (hexagon SW 22)
applying a tightening torque of 10 ±1 Nm When tightening the clamping screw
(1)
, the screw-in section
(6)
must be held in place with an open-end wrench
Connecting connection
lines to valve solenoids
with terminal box
6
5
2
1
3
4