F 037 300 069 (2013.05.21)
15
1.
Unscrew and remove the four M6 bolts (Bolt B) from housing base (see Figure 5),
2.
Hold the CIMS Mk IV upside down (sensor surface upward), make sure the four M6 bolts
(Bolt A) are lying loose in the intermediate piece (see Figure 5), so they do not block the
rotation.
3.
Rotate the housing base with respect to the intermediate piece in the desired position
(maximum angle of rotation 270
). If necessary, two hexagon socket screw keys can be
used with the holes in CIMS Mk IV, see Figure 6.
4.
Mount the four M6 bolts (Bolt B) in the intermediate piece (7.5Nm).
Bolt B (4x)
Bolt A (4x)
Figure 6: Holes of hexagon socket screw keys.
Figure 5: Remove screws.
Figure 4: CIMS Mk IV housing assembly component
names.
Bolt A (4x)
(countersunk)
Cover
Intermediate
piece
Housing
base
Adapter
ring
Summary of Contents for Rexroth CIMS Mk IV
Page 2: ...F 037 300 069 2013 05 21 2 ...
Page 31: ...F 037 300 069 2013 05 21 31 ...
Page 32: ...F 037 300 069 2013 05 21 32 ...
Page 33: ...F 037 300 069 2013 05 21 33 ...
Page 34: ...F 037 300 069 2013 05 21 34 A 2 F 037 A00 004 CIMS MK IV ATEX VERSION ...
Page 35: ...F 037 300 069 2013 05 21 35 ...
Page 36: ...F 037 300 069 2013 05 21 36 ...
Page 37: ...F 037 300 069 2013 05 21 37 ...
Page 38: ...F 037 300 069 2013 05 21 38 Appendix B DRAWING 3 033701 MOUNTING BORE PATTERN ON CYLINDER ...
Page 56: ...F 037 300 069 2013 05 21 56 Appendix D DECLARATION OF CONFORMITY EMC DIRECTIVE 2004 108 EC ...
Page 57: ...F 037 300 069 2013 05 21 57 Appendix E DECLARATION OF CONFORMITY ATEX DIRECTIVE 94 9 EG ...
Page 58: ...F 037 300 069 2013 05 21 58 ...
Page 59: ...F 037 300 069 2013 05 21 59 ...
Page 60: ......