![Bosch Rexroth 30 NFF2 Operating Instructions Manual Download Page 26](http://html.mh-extra.com/html/bosch/rexroth-30-nff2/rexroth-30-nff2_operating-instructions-manual_52746026.webp)
26/30
Bosch Rexroth AG
30, 50, 80 NFF2 | RE 51433-B/04.10
Technical data
13
General data 30, 50 NFF2
Table 6:
General data
30 NFF2
50 NFF2
Dimensions (width x height x depth) 600 x 1.160 x 580 [mm] 600 x 1.160 x 580 [mm]
Product weight
72 kg
84 kg
Temperature range for application
–10 - +60 °C
–10 - +60 °C
Storage temperature range
+5 - +30 °C
+5 - +30 °C
Admissible viscosity
10 - 200 mm
2
/s
10 - 200 mm
2
/s
Max. operating pressure
6 bar
6 bar
Max. oil temperature
60 °C
60 °C
Nominal flow
30 l/min
50 l/min
Nominal width suction / pressure
DN 30 / DN 25
DN 40 / DN 30
Protection class EN 60529/IEC529
IP54
IP54
Electric data
400 V / 50 Hz
400 V / 50 Hz
Pump motor power
1.1 kW
1.5 kW
General data 80 NFF2
Table 7:
General data
80 NFF2 0120
80 NFF2 0270
Dimensions (width x height x depth) 600 x 1.160 x 580 [mm] 650 x 1.390 x 1.020 [mm]
Product weight
90 kg
150 kg
Temperature range for application
–10 - +60 °C
–10 - +60 °C
Storage temperature range
+5 - +30 °C
+5 - +30 °C
Admissible viscosity
10 - 200 mm
2
/s
10 - 200 mm
2
/s
Max. operating pressure
6 bar
6 bar
Max. oil temperature
60 °C
60 °C
Nominal flow
80 l/min
80 l/min
Nominal width suction / pressure
DN 45 / DN 30
DN 45 / DN 30
Protection class EN 60529/IEC529
IP54
IP54
Electric data
400 V / 50 Hz
400 V / 50 Hz
Pump motor power
1.5 kW
2.2 kW
Considered standards and directives
Table 8:
Considered standards and directives
Directive 89/336 EEC
"Electromagnetic compatibility" (EMC directive)
97/23/EC
Pressure Equipment Directive