NOTE!
Malfunctions due to incorrect assembly and commissioning
The height-adjustable workstation may be damaged or its service life
shortened.
Install the lifting modules aligned and level at right angles and parallel
to the axis.
Do not apply bending loads to the lifting modules.
Initialize the lifting modules (RESET)
24,
before permanently
completing the mechanical connection.
NOTE!
Uncontrolled movements during initialization (RESET)
The lifting modules may be damaged or their service lives shortened.
Make sure that no mechanical connections limit the movement of the
lifting modules.
Control unit does not function if the contact bridge or the control unit
control strip is not inserted!
(Display:
A 69)
Carrying out a RESET (initialization):
Make sure that all plugs are properly connected.
correct
incorrect
4
4
Make sure that no mechanical connections limit the movement of the
lifting modules.
Keep the “DOWN” and “UP” buttons simultaneously pressed for
10 seconds, the lifting modules will move down to the mechanical
stop and shut off. Now release the buttons. The RESET is confi rmed
by an acoustic signal ringing three times. The lifting modules move
automatically to the lower operating point. The system is now ready for
operation (Display:
72).
1
2
RESET
!
3 842 546 327/2013-04
| MPS
Bosch Rexroth AG
3/32
DEUT
SCH
EN
GLISH
546327_2013-04_Anhang_de-en-zh.indd 3
546327_2013-04_Anhang_de-en-zh.indd 3
06.05.2013 08:40:27
06.05.2013 08:40:27