Specifications
RDH06101, RDH06111 – 6 720 888 202 (2019/07)
6
4
Specifications
Table 4
Type
RDH 06101
RDH 06111
Model
pressurised (closed) – depressurised (open)
Weight
[kg]
1.8
1.8
Dimensions
[mm]
250 x 144 x 100
Operating mode
continuous
Mains connection
Permanent electrical connection
Nominal voltage
[V]
220 - 240
Nominal power (230V)
[kW]
6.0
6.0
Class of protection in accordance with IEC 335-1
IP 24 (splash-proof)
Fuse protection
[A]
32
32
Frequency
[Hz]
50
50
Fittings connection
[Zoll]
3/8
1/2
Minimum flow pressure
[MPa (bar)]
0.1 (1.0)
Maximum flow pressure
[MPa (bar)]
1.0 (10.0)
Water volume at switch-on approx.
[l/min]
2.3
2.3
Water volume at switch-off approx.
[l/min]
1.8
1.8
Typical warm water output at 37 °C
[l/min]
3.0
3.0
Energy efficiency class
A
A
Load profile
XXS
XXS
Annual energy consumption
[kWh]
489
489
Daily energy consumption
[kWh]
2.270
2.270
Sound power level
[dB]
15
15
Hot water heating energy efficiency
[%]
38
38