Installation instructions
5
RDH06101, RDH06111 – 6 720 888 202 (2019/07)
Table 1
3
Installation instructions
Install the continuous-flow heater as described in the
illustrated section. Observe the instructions in the text.
3.1
Installation
I. Unpacking/scope of supply
•
Unpack the appliance and check for transport damage.
•
Dispose of the packaging and, where applicable, the old
appliance, in an environmentally conscious manner.
Table 2
3.1.1 Preparation for installation
CAUTION:
Important!
Only use the enclosed installation set.
•
Shut off water supply. The electrical connection
(connection cable) must be disconnected from the power
supply. Unscrew the fuse or switch off the circuit breaker.
•
There must be a clearance of approximately 60mm on all
sides of the appliance for installation.
•
Observe the technical data for the appliance.
•
RDH 06101:
Unscrew the screws on the housing cover and
remove the lid.
II. Wall mounting
•
Secure the appliance using the installation template,
screws and wall plugs so that it is vertical and flush against
the wall:
Table 3
•
RDH 06101, RDH 06111:
For an exposed electrical
connection, the different methods of routing the supply line
found on the assembly template must be observed.
•
RDH 06101, RDH 06111:
The sleeve must fit tightly round
the connection cable. If the sleeve is damaged during
installation, the holes must be sealed water-tight.
III. Water connection
A
Pressurised connection
B
Depressurised connection
•
Fit the jet regulator supplied.
•
Check the inserted filter and sleeve in the water inlet.
•
Ensure that the connection pipes are fitted to the adapter
along the axis of the pipes.
•
Tighten the union nuts firmly to the adapter with an open-
jawed spanner.
The T-piece and flexible connecting hose (for pressurised
connection) are available from a specialist store.
For a depressurised connection, a depressurised fitting must
be used, e.g. fitting BZ13051 which can be obtained as
a special accessory.
IV. Electrical connection
C
Flow switch
D
Temperature limiter
RDH 06101, RDH 06111
The installation of non plug-in ready appliances must be
undertaken by the respective utility operator or by a qualified
specialist company, who can also assist you when you are
requesting the approval of the utility company for installation
of the appliance.
The appliances must be connected with a NYM-J3x4 (mm
2
)
mains lead. Leads with a larger cross-section must not be used.
•
Connect the appliance in accordance with the connection
diagram on the strip terminal.
•
Screw the housing cover back on.
•
After installation, give the user the operating
instructions and explain how the appliance works.
RDH 06111
High level appliance
RDH 06101
Under counter appliances
1
Housing
2
Mounting (2 screws, 2 wall plugs)
3
Filter and sleeve (inserted in inlet)
4
Jet regulator and seal
5
Only for appliances with a permanent electrical
connection: Rubber grommet
1
Locate the appliance on the screw and press down.
2
Screw in the second screw through the mounting tab
and tighten.
Summary of Contents for RDH06101
Page 1: ...6 720 888 202 2019 07 HK Installation and operating instructions RDH06101 RDH06111 ...
Page 9: ...Guarantee 9 RDH06101 RDH06111 6 720 888 202 2019 07 1 2 RDH06101 RDH06111 ...
Page 10: ...Guarantee RDH06101 RDH06111 6 720 888 202 2019 07 10 3 ...
Page 11: ...Guarantee 11 RDH06101 RDH06111 6 720 888 202 2019 07 4 RDH06101 RDH06111 ...