Water connection (Fig. III)

 

X

Using the locking screw 15, the water connection can 
be aligned by ± 10 mm vertically.

 

X

Adapt the bend in the “hot” pipe so that it lines up 
with the hot-water outlet. In doing so, make sure that 
the “cold” elbow connection is not bent.

Attention: Ensure that a distance of at least 6 mm is 
maintained to live parts of the heater.

 

X

Connect the water outlet and inlet and tighten the se-
curing nut on the mounting bolt.

Checking for leaks and flushing the heater:

 

X

Turn on the hot-water tap.

 

X

Check that all pipe joints are properly sealed.

Electrical connection (Fig. IV)

 

X

As a matter of principle, the water connections must 
be completed first of all before the heater is connect-
ed to the electricity supply (400 V AC, 3-phase). The 
appliance should be wired up according to the circuit 
diagram on the inside of the cover.

 

X

To guarantee compliance to relevant safety regula-
tions, an all-pole separator must be fitted during in-
stallation. The contact opening must be at least 3 mm.

 

X

Terminal BZ 45Z20 (special accessories) can be used 
if the connecting cable is fed into the heater via one 
of the bottom holes 14a!

 

X

The wires must not interfere with the operation of re-
lease button A on the safety temperature limiter.

Installation note

 

X

The installation of non plug-in ready appliances must 
be undertaken by the respective utility operator or by 
a qualified specialist company, who can also assist 
you when you are requesting the approval of the util-
ity company for installation of the appliance.

Mounting the cover onto the heater 
(Fig. V)

 

X

When you mount the cover onto the heater, ensure 
that the switch knob and the switch spindle are cor-
rectly aligned.

Startup (Fig. VI)

The device is compliant to IEC 61000-3-12.

 

X

Switch on via the water heater fuses in the  domestic 
wiring.

 

X

Select Setting 2 on the appliance and check the water 
temperature.

At a low water-pipe pressure

 

X

Turn on additional cold-water taps and check whether 
the heater switches on. Remove the continuous-flow 
heater if the heater does not switch on (Fig. VI, A). 

 

X

Explain the appliance to the user and please give him 
the operating instructions.

Priority switch for combination with electric storage 
 heaters (Fig. VI, B)

If the heater is going to be operated in this way, a prior-
ity switch must be connected into the line connecting 
the L2 phase to the appliance. It should be mounted on 
the meter or distribution panel.

a, b Control line for the electricity supply company con-

nected to the coil input on the charging contactor

f1  Safety temperature limiter with mains terminals

f3  Priority switch (current relay)

l1  Mains terminal (only on 21 kW and 24 kW 

appliances)

Summary of Contents for RDH 1810

Page 1: ...Register your new Bosch now www bosch home com welcome en Installation and operating instructions tr Montaj ve Kullanma Kılavuzu RDH 1810 RDH 2110 RDH 2410 Multimatic 2 1 ...

Page 2: ...return valve must NOT be connected to the cold water X Do not use plastic pipes Steel or copper pipes are suitable for the cold water sup ply Insulated copper pipes are particu larly suitable for the hot water pipes X The continuous flow heater may only be installed in a frost free room It should be installed close to the tap that is used the most frequently X The dismounted appliance must be store...

Page 3: ... Important Make sure that the connecting cable is isolated from the mains electricity supply X Place hole 3 in the mounting template over the cold water inlet X Select the most suitable hole through which the con necting cable is be fed The connecting cable must pass through one of the six holes marked 14 Termi nal BZ 45Z20 can be used if the cable is fed into the water heater through one of the b...

Page 4: ...tton A on the safety temperature limiter Installation note X The installation of non plug in ready appliances must be undertaken by the respective utility operator or by a qualified specialist company who can also assist you when you are requesting the approval of the util ity company for installation of the appliance Mounting the cover onto the heater Fig V X When you mount the cover onto the heat...

Page 5: ...9 8 11 5 13 1 approx 50 C supply temperature 12 C 6 7 7 8 9 0 Minimum flow pressure of appliance MPa bar with flow limiter 0 6 0 8 0 9 without flow limiter 0 4 0 5 0 6 The pressure loss on the mixer must also be added Special accessories X BZ 45U20 Pipe set for use of the continuous flow heater as an under sink appliance X Intermediate terminal block BZ 45Z20 Required when the mains connecting cable i...

Page 6: ...perature X Slightly close the hot water tap The water flows through the appliance more slowly and reaches a higher temperature as a result Decreasing the water temperature X Mix with cold water Note about operation When a hot water tap is turned on by only a small amount the continuous flow heater operates at half power regardless of which setting 1 2 has been selected When a hot water tap is turned...

Page 7: ...he drawing off of water resulting in a reduction in the water temperature X The washer inside the hot water tap must be a non swelling type If you cannot resolve the problem yourself switch off the heater via the fuse in the domestic wiring Arrange for a service engineer to visit After sales service If you call the after sales service for assistance please specify the E no and FD no of your applianc...

Page 8: ...ibat kullanılmamalıdır X Hiçbir zaman plastik boru kullanmayınız Soğuk su girişi için bakır veya çelik boru lar en uygundur Sıcaklığa karşı yalıtılmış bakır borular özellikle tercih edilmelidir X Ani su ısıtıcısı donma tehlikesi olma yan bir yerde tesis edilmelidir Ancak cihaz en çok sıcak su kullandığınız yere yakın monte edilmelidir X Demonte edilmiş olan cihaz donma teh likesinden uzak saklanma...

Page 9: ...Robert Bosch Hausgeräte GmbH 9 000 913 849 28 10 13 ...

Page 10: ...geräte GmbH 9 8 11 7 10 3 4 5 6 12 Montageschablone Mounting template Montagesjabloon Szablon montażowy Gabarit de montage 14 14a 13 14a 3 2 1 14a Multimatic 2 1 I 12 12 14a 14 14a 14a 12 cold water supply холодной воды soğuk su giriși 3 II A ...

Page 11: ...Robert Bosch Hausgeräte GmbH 9 000 913 849 28 10 13 warm water горячей воды sıcak su cold water холодной воды soğuk su II B 2 1 II C ...

Page 12: ...9 000 913 849 28 10 13 Robert Bosch Hausgeräte GmbH adjusting distance from wall изменяемое расстояние до стены değișken duvar mesafesi 0 25 mm 0 25 mm II E 9 8 11 9 8 11 II D ...

Page 13: ...Robert Bosch Hausgeräte GmbH 9 000 913 849 28 10 13 A 14 a A 1 3 5 L2 L3 L1 L1 L2 L3 14 a 18kW 21kW 24kW IV 90 120 mm 10 15 cold холодная вода soğuk hot горячая вода sıcak III ...

Page 14: ...9 000 913 849 28 10 13 Robert Bosch Hausgeräte GmbH or или veya 1 2 3 Multimatic 1 2 Multimatic 1 2 Multimatic 1 2 V ...

Page 15: ...räte GmbH 9 000 913 849 28 10 13 1 2 3 4 VI A L 1 L 2 L 3 f 3 a b L1 L2 L3 PE l 1 2 1 3 6 5 4 f 1 only on 21 kW and 24 kW appliances только для нагревателей мощностью 21 кВт и 24 кВт yalnız 21 kW ve 24 kW lık cihazla VI B ...

Page 16: ...9 000 913 849 28 10 13 Robert Bosch Hausgeräte GmbH ...

Page 17: ...da elektrik akımının kesilmiş olduğundan emin olunuz X Şablondaki 3 numaralı deliği soğuk su girişi üzerine koyunuz X Kablo geçişi için uygun bir boşluk seçiniz Elektrik bağlantı kablosu yalnız 14 numaralı altı boşluğun birinden geçirilmelidir Eğer elektrik bağlantı kablosu alttaki 14a numaralı boşlukların birinden geçirilerek şofbene takılacaksa BZ 45Z20 klemensi Özel ek par ça kullanılabilir X M...

Page 18: ...ın ku manda tuşu A yı fonksiyonunda engellememelidir Kurulumla ilgili uyarı X Tak çalıştır şeklinde olmayan cihazların kurulumu ilgili elektrik tedarikçisi veya cihazın kurulumu için ilgili elektrik tedarikçisinden gerekli onayı almanız ko nusunda da size yardımcı olacak ehliyetli bir uzman firma tarafından yapılmalıdır Şofbeni kapatma Resim V X Şofben muhafaza kapağını yerine takarken şalterin ko...

Page 19: ...şık 38 C 9 8 11 5 13 1 Yaklaşık 50 C Giriş sıcaklığı 12 C 6 7 7 8 9 0 Şofbenin en düşük su akış basıncı MPa bar Su akışı ayarlayıcısı olduğu durumda 0 6 0 8 0 9 Su akışı ayarlayıcısı olmadığı durumda 0 4 0 5 0 6 Buna ayrıca banyo bataryasındaki basınç düşmesi de ilave edilir Özel aksesuar X Boru döşeme seti BZ 45U20 ani su ısıtıcısının lavabo altında kullanılması için X Ara klemensi BZ 45Z20 Elekt...

Page 20: ... Bu durumda musluk bir miktar kısılır böylece su ciha zın içinden daha yavaş geçer ve su daha fazla ısınır Su sıcaklığının düşürülmesi X Soğuk su musluğu açılarak su sıcaklığı azaltılabilir Kullanımla ilgi açıklamalar Sıcak su musluğunun sadece yarım açılırsa şofben önce den seçilmiş her iki programda da 1 2 yarı kapasitede çalışır Musluğun tam açılması durumunda şofben önceden be lirlenen kapasit...

Page 21: ...iz Şofben su alırken kapanıyor ve suyun sıcaklığı düşüyorsa X Sıcak su musluğuna takılan conta uygun değildir Eğer kendiniz arızayı gideremezseniz Sigortayı kapatınız ve bir teknisyen çağırınız Müşteri hizmetleri Müşteri hizmetlerinden aradığınızda lütfen cihazınızın E ve FD numaralarını bildiriniz Numaraları ani su ısıtıcısının alt tarafında bulabilirsiniz E Nr FD ROBERT BOSCH HAUSGERÄTE GMBH Tas...

Page 22: ......

Page 23: ......

Page 24: ...Robert Bosch Hausgeräte GmbH Carl Wery Str 34 81739 München Germany www bosch home com 9 000 913 849 10 13 ...

Reviews: