Professional Series TriTech AM Motion Detectors
with Anti-mask, LSN
Troubleshooting | en
27
Bosch Building Technologies
Reference Manual
2018.10 | 01 | F.01U.352.414
9.7
Detector LED flashes three times in a row repeatedly
Potential causes
–
Masking attempt is detected
–
The installer or an object is too close to the detector during the power-up period
9.8
Detector LED flashes four times in a row repeatedly
Potential causes
–
The detector failed during the routine self test
9.9
Detector LED flashes five times in a row repeatedly
Potential causes
–
The supply voltage is too low
9.10
Detector does not detect motion near the edge of the coverage
area
Potential causes
–
Microwave Doppler radar range too short
–
Installation height does not meet the recommendation listed in this document
–
Level alignment does not meet the requirement noted in this document