PRAESENSA
Configure the system | en
75
Bosch Security Systems B.V.
Configuration manual
2020-09 | V1.20 | PRAESENSA 1.20
5.5
Zone definitions
On the Zone definitions pages, the amplifier output channels and zone routing can be defined.
It is possible to configure:
–
–
–
5.5.1
Zone options
On the Zone options page, zones can be created. A zone is a group of audio outputs that, for
example, go to the same geographical area.
Configuration example
As an example, amplifiers that are part of a PRAESENSA system on an airport:
–
Audio outputs of amplifier 1 and amplifier 2 go to departure hall 1.
–
Audio outputs of amplifier 1 and amplifier 2 go to departure hall 2
Then, a zone can be created called Departure 1 to group the loudspeaker lines that go to
departure hall 1 and a zone called Departure 2 to group the loudspeaker lines that go to
departure hall 2.
–
Notice
that an audio output cannot be part of more than one zone. After an audio output
has been assigned to a zone, it is not allowed to assign the audio output to another zone.
Zone options page
1.
Below
Zone definitions,
click
Zone options:
2.
Select
,
enable
or
disable
each of the following items:
Item
Value
Description
Audio outputs
Selection
Shows
the available audio outputs to select.
> and <
Buttons
Using
the > and < buttons, selected outputs can be added
(>) to, or removed (<) from, assigned outputs
Name
Selection
Shows
the name of the zone by a dropdown list selection.
See Add a zone topic in this section. When using an
multifunction power supply Lifeline is default available to
select.
Volume settings
Selection
Opens
the Volume setting category to configure the
volume settings of the zone. See the Volume settings topic
in this section.
Add
Button
A new
zone can be added to the system configuration.
See Add a zone topic in this section.
Rename
Button
An existing
zone can be renamed. Automatically this name
is replaced everywhere in the configuration this zone is
used.
Delete
Button
An existing
zone can be deleted from the system
configuration. See Delete a zone topic in this section.
Submit
Button
Click
the Submit button to store the settings: Notice that
you always have to Save the configuration. See
Summary of Contents for PRAESENSA PRA-AD604