5.5.3
BGM routing
At the BGM routing page, background music (BGM) routing can be defined. A BGM routing
refers to an audio input in the system. Optionally, default zones and or default zone groups
can be connected to the routing. When the system is switched on, then the specified BGM is
routed to the connected zones and zone groups.
BGM routing configuration page
1.
Below
the Zone definitions page,
click
BGM routing:
–
A screen appears listed the following items:
2.
Select
,
enabl
e or
disable
each of the following items:
Item
Value
Description
Name
Selection
Shows
the name of the BGM routing
(dropdown list selection). See Add BGM
routing topic in this section.
Type
Selection
Selection
between zones and zone groups as
available routing.
Zones / Zone groups
Selection
The left box area
shows
the available zones
and zone groups. Zones (groups) are created
in
Zone options, page 75 and Zone grouping,
> and <
Buttons
Using
the > and < buttons, selected zones
and zone groups can be added to, or removed
from, Routing (the right area box).
Audio input
Selection
Select
the Audio input that provides the
background music.
Notice
that the inputs 9
up to 16 are
secured
(Dante/OMNEO
channels) to the amplifier. The same Audio
input may not be assigned to different BGM
routing. Each BGM routing must have a
unique
audio input.
Limit routing
Enable / Disable
Enable:
The center box area shows the zones
and zone groups that are allowed to receive
the BGM routing. This center box area is not
visible if the Limit routing checkbox is
disabled.
Using
the > and < buttons, selected
zones and zone groups (left area box) can be
added to, or removed from Limit Routing (the
middle area box).
See
also the Limit routing
topic in this chapter.
Routing
Selection
The right box area
shows
the zones and zone
groups that are assigned to the selected BGM
routing at system start‑up.
Using
the > and <
buttons, selected zones and zone groups (the
left or middle area box) can be added to, or
removed from Routing (right area box).