You can also check the latency histogram in the Dante controller. For example:
The latency scattered around it could be caused by an improperly configured switch in the
path between the PRA-APAS and PRAESENSA or between the clock master.
1.
Connect the PRA-APAS device closer to the PRAESENSA.
2.
Make sure that the switch is properly configured for IEEE1588-2008:
–
All QoS DiffServ have DSCP marking AF41(34).
–
EF(46) is properly configured to the correct queues.
10.10
Dante controller
In case of any irregularities and connection issues:
1.
Disconnect and reconnect the cables of your network.
2.
Restart the connected devices to refresh the system.
10.11
Firefox does not allow to login anymore
When you try to access the page of the PRA-APAS in the Firefox browser for login, the fault
message
Secure connection failed
appears.
This issue is related to a particular installation of Firefox. It usually happens when Firefox
internal certificate trust store is corrupted.