PR109B-PR110B Installer Reference Guide

2

Bosch Security Systems    09/11    PR109B-PR110BIRG  FTR1.1

The PR109B and PR110B LAN readers feature our proprietary 40 bit 
transmission format and can be used to provide alarm and or ac-
cess control functionality when used on selected Solution security 
control panels.  

The PR109B and PR110B readers include red, green and blue indica-
tors which are used to show area and or door lock status at all times.
The reader connects to the control panel via the RS485 encrypted 
LAN and occupies a standard keypad position in the panel configu-
ration.  

Various options can be configured via the Devices - Keypad & Read-
ers menu in panel programming.  User access events are stored in 
the panel log and can also be reported if required. 

Reader Addressing

Each reader fitted to the system must be assigned a unique address on the LAN.   
The PR109B and PR110B readers include a rotary address switch for quick selection.  The following table shows the  
address setting for each reader as well as the number of keypad, reader devices each panel can support.

Reader Compatibility

Panels Supported

Version

Keypads Supported

Solution 16i

2.19

Up to 8

Solution 16X

2.00

Up to 8

Solution 144 GRAPHIC

2.00

Up to 16

Solution GRAPHIC

2.00

Up to 16

Table 1: LAN Reader Compatibility

LAN Readers

PR109B - Black and PR110B - White

Figure 1: PR110B Reader

Reader Address Setting

Address No Keypad No

S

olution 16i P

anel

S

olution 16X P

anel

S

olution 144 P

anel

S

olution GR

APHIC P

anel

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

13

13

14

14

15

15

16

16

Table 2: Address Table

Figure 2: Address Switch

i

Note

  Only 1 reader can be assigned to each address.  All 

readers are supplied from the factory set to address 
1.  You must power cycle the panel or perform a 
LAN scan whenever you change the reader address.

Box Contents

The PR109B and PR110B contains the following parts.

Reader Base Unit
Reader Cover
Mounting Template
Instruction Sheet
2 x (M3 x 6mm) Hex Screw
1 x 2mm Hex Key

Summary of Contents for PR109B

Page 1: ...PR109B and PR110B LAN Reader Module Security System Installer Reference Guide EN Security Systems ...

Page 2: ...clude a rotary address switch for quick selection The following table shows the address setting for each reader as well as the number of keypad reader devices each panel can support Reader Compatibility Panels Supported Version Keypads Supported Solution 16i 2 19 Up to 8 Solution 16X 2 00 Up to 8 Solution 144 GRAPHIC 2 00 Up to 16 Solution GRAPHIC 2 00 Up to 16 Table 1 LAN Reader Compatibility LAN...

Page 3: ...r The readers also include an egress input and lock output which can be used to control door access if required i Note Using the on board lock output is not recommend ed when the reader is being used on an external wall of the building In this case it is recommended that you run the lock control wires directly to an output located on the main panel or output ex pander module located inside the bui...

Page 4: ...lowest level See the Devices Keypads Readers Commands menu in panel programming i Note Setting the reader volume to off will stop all audible warning signals at the reader Reader Alert Tones Event Alert Tone Emitted Fire Alarm If the system registers a fire alarm the reader will sound 3 short beeps fol lowed by a 1 5 second pause This will repeat until reset by the user or until the siren run time...

Page 5: ...the associated access group or door assignment is triggered i Note The on board lock output will operate for a fixed time period of 5 seconds when triggered If a dif ferent time is required then you should use another output on the system to operate the door lock The lock output and LAN power supply are not de signed to operate and power the door lock directly You should always fit a relay and pro...

Page 6: ...l programming if required Lock Output EGRESS INPUT N O BK RD WH BL YL GN MODULE LAN CONTROL PANEL A B TO DOOR LOCK 12V DF70 N O COM N C CM444 Relay Card RED BLACK WHITE BLUE YELLOW GREEN LAN LAN LAN A LAN B LOCK EGRESS Wiring Legend DOOR LOCK PROTECTION DIODE CM444B RELAY CARD Egress Input R D CM720B or CM723B Power Supply Battery backed up To Cont r o l P a n e l The egress input is low 0V to tri...

Page 7: ...utput 500mA Egress Input Low to trigger Can be disabled via software control Dimensions 74mm W 23mm D 116mm H CM444B 46mm W 12 5mm D 12mm H Environment 30 to 55 C RH 5 to 85 at 30 C non condensing Fixing Method The PR109B and PR110B should be mounted on a sturdy vertical wall using fixtures appropriate for the wall construction type Warranty 3 years from date of manufacture return to base N12138 N...

Page 8: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2011 Bosch Security Systems PR109B PR110BIRG Issue FTR1 1 ...

Reviews: