background image

PR109B and PR110B 
LAN Reader Module

Security System

Installer Reference Guide

EN

Security Systems

Summary of Contents for PR109B

Page 1: ...PR109B and PR110B LAN Reader Module Security System Installer Reference Guide EN Security Systems ...

Page 2: ...clude a rotary address switch for quick selection The following table shows the address setting for each reader as well as the number of keypad reader devices each panel can support Reader Compatibility Panels Supported Version Keypads Supported Solution 16i 2 19 Up to 8 Solution 16X 2 00 Up to 8 Solution 144 GRAPHIC 2 00 Up to 16 Solution GRAPHIC 2 00 Up to 16 Table 1 LAN Reader Compatibility LAN...

Page 3: ...r The readers also include an egress input and lock output which can be used to control door access if required i Note Using the on board lock output is not recommend ed when the reader is being used on an external wall of the building In this case it is recommended that you run the lock control wires directly to an output located on the main panel or output ex pander module located inside the bui...

Page 4: ...lowest level See the Devices Keypads Readers Commands menu in panel programming i Note Setting the reader volume to off will stop all audible warning signals at the reader Reader Alert Tones Event Alert Tone Emitted Fire Alarm If the system registers a fire alarm the reader will sound 3 short beeps fol lowed by a 1 5 second pause This will repeat until reset by the user or until the siren run time...

Page 5: ...the associated access group or door assignment is triggered i Note The on board lock output will operate for a fixed time period of 5 seconds when triggered If a dif ferent time is required then you should use another output on the system to operate the door lock The lock output and LAN power supply are not de signed to operate and power the door lock directly You should always fit a relay and pro...

Page 6: ...l programming if required Lock Output EGRESS INPUT N O BK RD WH BL YL GN MODULE LAN CONTROL PANEL A B TO DOOR LOCK 12V DF70 N O COM N C CM444 Relay Card RED BLACK WHITE BLUE YELLOW GREEN LAN LAN LAN A LAN B LOCK EGRESS Wiring Legend DOOR LOCK PROTECTION DIODE CM444B RELAY CARD Egress Input R D CM720B or CM723B Power Supply Battery backed up To Cont r o l P a n e l The egress input is low 0V to tri...

Page 7: ...utput 500mA Egress Input Low to trigger Can be disabled via software control Dimensions 74mm W 23mm D 116mm H CM444B 46mm W 12 5mm D 12mm H Environment 30 to 55 C RH 5 to 85 at 30 C non condensing Fixing Method The PR109B and PR110B should be mounted on a sturdy vertical wall using fixtures appropriate for the wall construction type Warranty 3 years from date of manufacture return to base N12138 N...

Page 8: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2011 Bosch Security Systems PR109B PR110BIRG Issue FTR1 1 ...