![Bosch Power Max 2 Installation And Operating Instructions Manual Download Page 8](http://html.mh-extra.com/html/bosch/power-max-2/power-max-2_installation-and-operating-instructions-manual_38051008.webp)
en | 8 | Installation and Operating Instructions |
Power Max 2
Charging Station
579367 | REV A | 25.07.2016
5 Specifications
Model
EL-51866-30XX
EL51866-40XX
Charging Interface
SAE J1772 compliant plug
Input Rating
208-240 Vac, single-phase,
30 A max, 60 Hz
208-240 Vac, single-phase,
40 A max, 60 Hz
Wiring for Hard-wired Models
L1, L2, and Ground, hard-wired with terminal block; bottom-fed
Wall Plug for Cord-connected Models
NEMA 6-50P
Output Rating
208-240 Vac, single phase, 30 A max.,
60 Hz, 7.2 kW
208-240 Vac, single phase, 40 A
max., 60 Hz, 9.6 kW
Standby Power
<5W
Metering
Embedded non-revenue grade meter with 1% accuracy
Internal Residual Current Detection
20 mA CCID per UL 2231
Upstream Breaker
2-pole 40 A breaker on dedicated
circuit, non-GFCI type (if hard-wired)
2-pole 50 A breaker on dedi-
cated circuit, non-GFCI type
Electrical Protection
Over current, short circuit, over voltage, under voltage, ground fault,
surge protection, over temperature
Status Indicators
AC present, charging, fault
Buttons/Switches
Charger on/off, stop charging
Option: Network Interface
WLAN
Operating Temperature
-22°F to +122°F (-30°C to +50°C)
Humidity
95% related humidity, non-condensing
Charging Cable Length
18 ft (5.5 m) or 25 ft (7.6 m) straight cable
Ingress Protection
Type 3R
Cooling
Natural cooling
Dimension (W×H×D)
12.6×10.3×4.5 in. (320×260×115 mm), excluding charging cable, mount-
ing plate, and cable holder
Net Weight
5 lb (2 kg) excluding charging connector and cable
Certificate
UL, cUL