English |
25
Bosch Power Tools
2 609 140 621 | (25.6.09)
Technical Data
Digital Laser Rangefinder
PLR 50
Article number
3 603 K16 300
Measuring range
0.05–50 m
A)
Measuring accuracy (typically)
±
2.0 mm
B)
Lowest indication unit
1 mm
Operating temperature
– 10 °C ... +50 °C
C)
Storage temperature
– 20 °C ... +70 °C
Relative air humidity, max.
90 %
Laser class
2
Laser type
635 nm, <1 mW
Laser beam diameter (at 25 °C) and
at 10 m distance, approx.
6 mm
Batteries
Rechargeable batteries
4 x 1.5 V LR03 (AAA)
4 x 1.2 V HR03 (AAA)
Battery live, approximately
– Individual measurements
– Continuous measurement
30000
D)
5 h
D)
Weight according to
EPTA-Procedure 01/2003
0.18 kg
Dimensions
58 x 104 x 36 mm
Degree of protection
(excluding battery compartment)
IP 54 (dust and splash
water protected)
A) The working range increases depending on how well the laser light is
reflected from the surface of the target (scattered, not reflective) and
with increased brightness of the laser point to the ambient light intensity
(interior spaces, twilight). In unfavourable conditions (e.g. when meas-
uring outdoors at intense sunlight), it may be necessary to use the target
plate.
B) In unfavourable conditions (e.g. at intense sunlight or an insufficiently
reflecting surface), the maximum deviation is
±
10 mm per 50 m. In favour-
able conditions, a deviation influence of
±
0.05 mm/m must be taken into
account.
C) In the continuous measurement function, the maximum operating
temperature is +40 °C.
D) Fewer measurements are possible when using 1.2 V rechargeable
batteries as compared with 1.5 V batteries.
Please observe the article number on the type plate of your measuring
tool. The trade names of the individual measuring tools may vary.
The measuring tool can be clearly identified with the serial number
21
on the type plate.
OBJ_BUCH-946-002.book Page 25 Thursday, June 25, 2009 9:00 AM