24
| English
1 618 C00 93G | (23.1.14)
Bosch Power Tools
Assembly
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for the measuring tool.
To open the battery lid
7
, press on the latch
8
and fold the battery lid up.
Insert the batteries. When inserting, pay attention to the correct polarity
according to the representation on the inside of the battery lid.
Always replace all batteries at the same time. Only use batteries from one
brand and with the identical capacity.
Remove the batteries from the measuring tool when not using it
for extended periods.
When storing for extended periods, the batter-
ies can corrode and self-discharge.
Operation
Initial Operation
Protect the measuring tool against moisture and direct sun light.
Do not subject the measuring tool to extreme temperatures or var-
iations in temperature.
As an example, do not leave it in vehicles for
longer periods. In case of large variations in temperature, allow the
measuring tool to adjust to the ambient temperature before putting it
into operation.
Avoid heavy impact to or falling down of the measuring tool.
Dam-
age to the measuring tool can impair its accuracy. After heavy impact
or shock, compare the laser lines with a known horizontal or vertical
reference line.
Switch the measuring tool off during transport.
When switching off,
the levelling unit, which can be damaged in case of intense movement,
is locked.
Switching On and Off
To
switch on
the measuring tool, slide the On/Off switch
5
to one of the
“On”
positions (
).
Do not point the laser beam at persons or animals and do not look
into the laser beam yourself, not even from a large distance.
To
switch off
the measuring tool, slide the On/Off switch
5
to the
“Off”
position. When switching off, the levelling unit is locked.
Off On On