background image

PBC-60 - power supply and battery charger | 3

Parts Included

The components supplied are as follows:

Power supply

Temperature sensor

Plug

-

1 x 2-pin for mains (primary AC) connection

-

3 x 2-pin

-

1 x 4-pin

Accompanying documentation

Technical Specifications

Output values:

Output voltage:

12 V mode

10-15 V

24 V mode

20-30 V

Output current:

12 V mode

Max. 5 A

24 V mode

Max. 2.5 A

Output power:

60 W (constant)

Input values:

Input voltage:

100-240 VAC, 50-60Hz

Input current (AC):

Max. 2 A, to the specified max. load at

85 V~

Output values for the battery:

Output voltage:

12 V mode

10-15 V

24 V mode

20-30 V

Output current for charging the battery:

12 V mode

700 mA

24 V mode

350 mA

Periodic battery checks - approx. every 6 minutes.
Protection from total battery discharge:

12 V mode

9.5 V

24 V mode

19 V

The power supply switches to normal operation as soon as the AC incoming

voltage has normalized.
Temperature equalization is performed by an external NTC resistor.
Reverse battery protection

Environment variables:

Working temperature

-5°C (23°F) to +50°C (122°F)

Storage temperature

-20°C (-4°F) to +60°C (140°F)

Relative humidity

5% to 95%

Ordering Information

PBC-60 - power supply and battery charger

A power supply unit with an integrated battery

charging device.

APS-PBC-60

www.boschsecurity.com

Summary of Contents for PBC-60

Page 1: ...d The following applies to the battery mode If the input voltage is less than 85 V the power supply switches to Battery operation mode and the yellow LED lights up next to BOP The OFF button is only activated in Battery operation mode This button is pressed to switch the output voltage off Restart is only possible when the alternating current supply is restored This power supply unit can be switch...

Page 2: ...s are shown in the diagrams below 1 2 3 1 Length 140 mm 5 51 in 2 Width 105 mm 4 13 in 3 Height 60 mm 2 36 in Alternatively it can be screw mounted directly to the wall There are pre drilled holes for this purpose on the base of the housing These holes have the following dimensions 0 0 Ø 1 Ø 2 A B C D E Ø 1 8 7 mm 0 34 in Ø 2 4 7 mm 0 19 in A 5 5 mm 0 22 in B 24 mm 0 94 in C 99 5 mm 3 92 in D 8 1 ...

Page 3: ...tery Output voltage 12 V mode 10 15 V 24 V mode 20 30 V Output current for charging the battery 12 V mode 700 mA 24 V mode 350 mA Periodic battery checks approx every 6 minutes Protection from total battery discharge 12 V mode 9 5 V 24 V mode 19 V Thepowersupply switchesto normaloperationassoon asthe AC incoming voltage has normalized Temperature equalization is performed by an external NTC resist...

Page 4: ...V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 40 2577 284 Fax 31 40 2577 330 emea securitysystems bosch com www boschsecurity com Asia Pacific Robert Bosch SEA Pte Ltd Security Systems 11 Bishan Street 21 Singapore 573943 Phone 65 6258 5511 Fax 65 6571 2698 apr securitysystems bosch com www boschsecurity com Represented by Bosch Security Systems Inc 2010 Data subject to change without...

Reviews: