14
en | Compatibility with older EOL modules
PAVIRO End-of-line supervision
module
2019-01 | V2 | F01U350870
Bosch Security Systems B.V.
5
Compatibility with older EOL
modules
Notice!
Different hardware and software versions can
be used in the same system; however, the
lowest Cg must be taken as the maximum Cg
for the system.
The limits in this section are valid for PVA-1WEOL in combination with
PVA-4CR12 or PVA-4R24 hardware version 02/00.
PVA-1WEOL - HW 1.1, FW 1.1
Minimum R
G
1.5 MΩ
Maximum Cg
200
nF
Number of modules
60
PVA-1WEOL - HW 1.1, FW 1.2
Minimum R
G
1.5 MΩ
Maximum Cg
800
nF
Number of modules
58