13

Customer Service

Contact Customer Service if your appliance needs repair 

(see phone number below). Our Customer Service will be 

happy to provide you with information about an 

authorized servicer near you.

Model (E) number and FD number

When you contact Customer Service, please have the 

Model (E) number and the FD number for your appliance 

available.
You can find this information on the rating label:

in the Appliance Document List

on the underside of the appliance

Gas

Pressure "wc

BTU/h

kW

M
(valve adjustment 

screw setting)

Natural gas

77

3400

1

B

Propane

11

54

3400

1

A

Natural gas

7

102

6000

1.76

B

Propane

11

71

6000

1.76

A

Natural gas

7

125

9010

2.64

B

Propane

11

88

9010

2.64

A

Natural gas

7

1 - 161

17000

4.98

B

2 - 74

Propane

11

1 - 105

15700

4.6

A

2 - 51


A

Rating label location

$

0DLQ6WUHHW6XLWH

,UYLQH&$

ZZZERVFKKRPHFRP

Summary of Contents for NGM8657UC

Page 1: ...Installation Manual Gas Cooktop NGM8657UC ...

Page 2: ...t Gas Supply 9 Connect Electrical Supply 10 Burner Cap and Burner Base Placement 10 Install Burner Grates 10 Check the Installation 11 Conversion to LP Gas 11 Converting the Pressure Regulator 11 Replacing the Nozzles 12 Adjusting the Gas Valves 12 Customer Service 13 9 Safety DefinitionsSafetyDefinitions 9 WARNING This indicates that death or serious injuries may occur as a result of non observan...

Page 3: ...WKH JDV VXSSOLHU V LQVWUXFWLRQV I RX FDQQRW UHDFK RXU JDV VXSSOLHU FDOO WKH ILUH GHSDUWPHQW QVWDOODWLRQ DQG VHUYLFH PXVW EH SHUIRUPHG E D TXDOLILHG LQVWDOOHU VHUYLFH DJHQF RU WKH JDV VXSSOLHU 51 1 I WKH LQIRUPDWLRQ LQ WKHVH LQVWUXFWLRQV LV QRW IROORZHG H DFWO D ILUH RU H SORVLRQ PD UHVXOW FDXVLQJ SURSHUW GDPDJH SHUVRQDO LQMXU RU GHDWK 1HYHU 2SHUDWH WKH 7RS 6XUIDFH RRNLQJ 6HFWLRQ 51 1 RI WKLV SSOLD...

Page 4: ...National Fuel Gas Code ANSI Z223 1 NFPA 54 or in Canada the Natural Gas and Propane Installation Code CSA B149 1 The appliance must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code NFPA 70 latest edition or in Canada the Canadian Electric Code CSA C22 1 02 Electric Safety WARNING Before you plug in an electrical cord or turn...

Page 5: ...es Installer show the owner where the gas shut off valve is located Related Equipment Safety The appliance should only be used if installed by a qualified technician in accordance with these installation instructions The manufacturer is not responsible for any damage resulting from incorrect installation Remove all tape and packaging before using the appliance Destroy the packaging after unpacking...

Page 6: ... VAC connection Plan the installation so that the power connection is accessible from the front of the cabinet Gas Requirements The cooktop is shipped from the factory for use with natural gas For use with LP conversion a certified technician or installer must do the conversion Supply Pressure Natural Gas 7 inches water column 17 4 Millibars Propane Gas 11 inches water column 27 4 Millibars The pr...

Page 7: ... has been made Note All measurements given must be precisely followed If nonstandard cabinets are used make sure they are installed with minimum dimensions shown in the following image for installation in a kitchen island Ventilation Requirements We strongly recommend the installation of ventilation with the appliance The appliance must be installed according to the ventilation instructions 9 CAUT...

Page 8: ...mable intermediate floor e g metal or plywood 3 8 10 mm from the base of the cooktop This will prevent access to the base of the cooktop The distance from the intermediate floor to the power supply connection for the appliance must be at least 3 8 10 mm Install the Cooktop 9 WARNING Before you plug in an electrical cord or turn on power supply make sure all controls are in the OFF position 9 CAUTI...

Page 9: ...gulator Always use a new flex line Checking Gas Line for Leaks Check supply line connections for leaks using a soap solution or non corrosive leak detection fluid Do not use a flame of any sort 1 Turn on gas 2 Apply a soap solution or non corrosive leak detection fluid to all joints and fittings in the gas connection between the shut off valve and the cooktop Include gas fittings and joints in the...

Page 10: ...ner parts are not properly placed one or more of the following may occur Burner flames are too high Flames shoot out of burners Burners do not ignite Burner flames light unevenly Burner emits gas odor Placing Burner Parts After electrical connection is complete assemble the burner parts correctly and evenly When assembling the burner parts make sure that the burner head is placed on the base in su...

Page 11: ...Converting the Pressure Regulator Locate the pressure regulator on the bottom right end of the cooktop Note The arrow on the back of the regulator must point in the direction of the gas flow to the cooktop 1 Remove the hexagon shaped cap from the regulator making sure not to dislodge the gasket on the cap or the spring inside the regulator 2 Grasp the plastic button stem firmly and pull it forcefu...

Page 12: ...2 Remove the control knobs from the gas valves and remove the white ring that is underneath A flexible black rubber sealing ring will be visible Below the left upper position of that seal there is a visible black Star T10 screw partly hidden by the seal Press the rubber seal aside a bit to meet the screw with a long thin T10 screwdriver The dual flame burner has 2 setting screws Never remove the s...

Page 13: ... number for your appliance available You can find this information on the rating label in the Appliance Document List on the underside of the appliance Gas Pressure wc BTU h kW M valve adjustment screw setting Natural gas 7 77 3400 1 B Propane 11 54 3400 1 A Natural gas 7 102 6000 1 76 B Propane 11 71 6000 1 76 A Natural gas 7 125 9010 2 64 B Propane 11 88 9010 2 64 A Natural gas 7 1 161 17000 4 9...