Safety Precautions

Installation should be performed by qualified
service personnel only in accordance with the
National Electrical Code or applicable local
codes.

Power Disconnect. Units with or without 
ON-OFF switches have power supplied to the
unit whenever the power cord is inserted into the
power source; however, the unit is operational
only when the ON-OFF switch is in the ON
position. The power cord is the main power
disconnect for all units. 

CAUTION: TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT REMOVE COVER
(OR BACK). NO USER SERVICEABLE PARTS
INSIDE.  REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.

This symbol indicates the presence of
uninsulated “dangerous voltage” within the
product’s enclosure that can cause an electric
shock.

This symbol indicates the presence of
important operating and maintenance
(servicing) instructions in the literature
accompanying the appliance.

For Indoor Product

1.

Water and Moisture

- Do not use this unit near

water - for example, in a wet basement, in an
unprotected outdoor installation or in any area
classified as a wet location.

2.

Object and Liquid Entry

- Never push objects of

any kind into this unit through openings, as they
might touch dangerous voltage points or create
short circuits, resulting in a fire or electrical
shock. Never spill liquid of any kind on the unit.

3.

Power Cord and Power Cord Protection

- For

units intended to operate with 230VAC, 50Hz,
the input and output power cord must comply
with the latest versions of IEC Publication 227 or
IEC Publication 245. 
Power supply cords should be routed so they are
not likely to be walked on or pinched. Pay
particular attention to location of cords and plugs,
convenience receptacles, and the point of exit
from the appliance.

4.

Overloading

- Do not overload outlets and

extension cords; this can result in a risk of fire or
electrical shock.

For Outdoor Product

Power Lines

- An outdoor system should not be

located in the vicinity of overhead power lines,
electric lights or power circuits, or where it may
contact such power lines or circuits. When
installing an outdoor system, extreme care should
be taken to keep from touching power lines or
circuits, as this contact might be fatal. U.S.A.
models only - refer to the National Electrical
Code Article 820 regarding installation of CATV
systems.

For Rack-mount Product

1.

Ventilation

- Do not place this equipment in a

built-in installation or rack, unless proper
ventilation is provided, or the manufacturer's
instructions were followed. The equipment must
not exceed its maximum operating temperature
requirements.

2.

Mechanical Loading

- When rack-mounting the

equipment, ensure that a hazardous condition is
not created by uneven mechanical loading.

Cover Removal

WARNING: Removal of the cover should only be 
performed by qualified service personnel - not user 
serviceable. The unit should always be unplugged before
removing the cover and remain unplugged while the
cover is removed.

Summary of Contents for MON150CL

Page 1: ...Instruction Manual EN MON150CL 15 inch Color LCD Flat Panel Display Monitor ...

Page 2: ...rical shock or other hazards 9 Safety Check Upon completion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of power supply to use contact your dealer or local power company For units intended to operate from ...

Page 3: ... Power Cord and Power Cord Protection For units intended to operate with 230VAC 50Hz the input and output power cord must comply with the latest versions of IEC Publication 227 or IEC Publication 245 Power supply cords should be routed so they are not likely to be walked on or pinched Pay particular attention to location of cords and plugs convenience receptacles and the point of exit from the app...

Page 4: ...ications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the s...

Page 5: ...LATION 7 5 1 Power 7 5 2 Desktop Installation 8 5 3 Connecting the Composite Video Signal to the Monitor 8 5 4 Connecting the Y C S video Signal to the Monitor 8 5 5 Connecting Audio to the Monitor 8 5 6 Connecting the Analog VGA Signal to the Monitor 9 5 7 Ventilation 9 6 0 OPERATION 9 6 1 Front Panel Controls 9 6 2 On screen Display OSD Menu 9 7 0 ON SCREEN DISPLAY MENU CONFIGURATION 11 7 1 CVBS...

Page 6: ... 2005 Key A AUTO Input Button B Buttons C MENU Button D Power LED Identification E Power Button A DC input B VGA input C Video CVBS input D Y C input E Audio input Fig 1 Front Panel Fig 2 I O Connectors MON150CL E D C B A A B C D E Figure 2 I O Connectors Figure 1 Front Panel ...

Page 7: ... DPMS it is supported by Plug Play and complies with DDC1 2B 3 1 Features 100 to 240 VAC Power Supply NTSC PAL Auto Detect High Resolution 1024 X 768 XGA PC Input Video Input Audio Input Y C Input OSD with Multiple Languages 4 0 INTRODUCTION 4 1 Monitors The MON150CL 15 inch 38 cm Color Liquid Crystal Display Monitor displays PAL or NTSC standard color pictures in CCTV systems The MON150CL monitor...

Page 8: ...o A 5 3 Connecting the Composite Video Signal to the Monitor There is one 1 RCA connector located on the rear of the monitor for composite video input please see Figure 2 on Page 6 Also included is one 1 RCA to BNC adapter used to connect a BNC cable line as shown in Photo B and Photo C Photo B Photo C 5 4 Connecting the Y C S video Signal to the Monitor There is one 1 mini DIN type connector for ...

Page 9: ...to turn on or turn off the monitor 6 2 On screen Display OSD Menu 6 2 1 Video Setting CVBS S VIDEO Saturation 1 Press Menu to open the OSD Main menu 2 Press the or button to highlight an option then press Menu to modify the value of the option Contrast Adjusts the contrast value 0 100 Brightness Adjusts the brightness value 0 100 Tint Adjusts the tint value NTSC only 0 100 Saturation Adjusts the c...

Page 10: ...equency Auto Colour Automatically adjusts the color temperature Exit Exits the Function OSD Menu setting 6 2 5 OSD Menu CVBS S VIDEO RGB VGA Language Opens the Language Selection Menu Select one of the following English Deutsch Francais Italiano Espanol Simple Chinese Traditional Chinese Japanese OSD Adjusts the OSD horizontal position H Position 0 100 OSD Adjusts the OSD vertical position V Posit...

Page 11: ...URATION 7 1 CVBS Mode CVBS Video Setting Contrast Brightness Tint Color Volume Exit OSD Menu Language OSD H Position OSD V Position OSD Timer Translucent Exit On Off On Off English Deutsch Francais Italiano Espanol Simple Chinese Japanese Traditional Chinese Miscellaneous Exit Signal Source Mode Select Reset Exit Yes No D Sub CVBS S Video ...

Page 12: ... Systems May 20 2005 7 2 VGA Mode RGB VGA Colour Contrast Picture H Position V Position Sharpness Phase Clock Exit Function Auto Adjust Yes No Auto Position Auto Phase Auto Clock Auto Colour Exit Brightness Gamma Correct Red Green Blue Exit Colour Adjust Exit Yes No Yes No Yes No Yes No ...

Page 13: ...s not supported by the MON150CL Please change the PC settings to one of the supported VGA Timing Mode combinations listed OSD Menu Language OSD H Position OSD V Position OSD Timer Translucent Exit English Deutsch Francais Italiano Espanol Simple Chinese Japanese Traditional Chinese Miscellaneous Exit Signal Source Mode Select Reset Exit On Off On Off Yes No D Sub CVBS S Video VGA Timing Modes 640 ...

Page 14: ...EN 14 MON150CL Instruction Manual Bosch Security Systems May 20 2005 ...

Page 15: ...EN 15 MON150CL Instruction Manual Bosch Security Systems May 20 2005 ...

Page 16: ... security sales us bosch com http www boschsecurity us Europe Middle East Africa Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 0 40 27 83955 Fax 31 0 40 27 86668 emea securitysystems bosch com http www boschsecurity com Asia Pacific Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone 65 6319 3450 Fax 65 6319 3499 apr securitysystems bosch ...

Reviews: