Solar Energy 

 

 

 

 

 

 

 

 

 

2

 

General product properties 

2.1

 

Specifications for the product se-
ries  

 

Basic specifications for the 

μ

m-Si plus EU1510 prod-

uct series

 

 

Efficiency  

7.3 – 9.0 %

 

Output  

105 – 130 Wp  

Grading  

-0/ +4.99 Wp  

Initial Voc  
(before stabilization) 

90 V  

Stab. Voc  
(after stabilization)  

89 V  

Temperature coefficients 
 
Voc  
Isc  
Pmpp  

 
 
-0.37 %/K 
+0.08 %/K 
-0.33 %/K 

System voltage  

1,000 V  

Reverse-current resis-
tance  

6 A 

Application class accord-
ing to IEC 61730 

A (buildings, commercial) 
A-1 (accessible ground-
mounted and on-roof in-
stallations)

 

Protection class 

II 

Weight 

25 Kg + 0.7  

Surface 

1.43 m² 

Weight/surface 

16.78 Kg/m² 

 
 

Note:  

All power ratings on the data sheet and product label 
refer to a stabilized solar module output.  
 
 

Note:  

Electrical parameters are typical mean values from 
historical production data. Bosch Solar Energy AG 
does not assume any guarantee for the accuracy of 
this data for future production batches. All data and 
figures are subject to a tolerance of 10 %, unless 
specified otherwise.  
 
 
 

 
 
 
 
 

Warning! 

Under normal conditions, a photovoltaic module is 
likely to experience conditions that produce more cur-
rent and/or voltage than reported at standard test 
conditions. Accordingly, the values of Isc and Voc 
marked on this module should be multiplied by a fac-
tor of 1,25 when determining component voltage rat-
ings, conductor current ratings, fuse sizes, and size of 
controls connected to the PV output! 
 
 

2.2

 

Specifications for the junction box 
system  

 

Junction box system properties 

 

Cable cross-section  

2.5 mm²  

Length of connecting cable 
with PV-KST 4 coupler 
socket (MINUS)  

1,000 mm  

Length of connecting cable 
with PV-KBT 4 MC4 coupler 
plug (PLUS)  

500 mm  

Contact material  

Tin-plated copper  

Conductive material  

Copper  

Rated voltage  

1,000 V  

Rated current  

10 A  

Protection rating for junction 
box  

IP 65  

UV-resistant & weatherproof  

Yes  

Flame class  

UL 94-V0  

Temperature range  

-40 to +90 °C  

 

 

 

   

 

Summary of Contents for mm-Si plus EU1510 Series

Page 1: ...1 Solar Energy Planning and Installation Instructions μm Si plus EU1510 For Specialists Version ENG 2011 12 ...

Page 2: ...rtification 6 3 INSTRUCTIONS ON THE SYSTEM LAYOUT 6 3 1 General instructions 6 3 2 Guidelines on the electrical system layout 7 3 3 Guidelines for attaching solar modules up to 2 400 Pa 8 3 4 Transport and storage before installation 10 4 STANDARDS AND REGULATIONS 11 5 INSTALLATION 11 5 1 Safety instructions 11 5 2 Storage and transport on the construction site 12 5 3 Checks before installation 12...

Page 3: ...cases Notes contain important information regard ing situations where there is no hazard to human health or equipment 1 3 General safety instructions For your own safety and that of your employees or third parties and for the protection of the system you are installing please follow the safety instructions in this section as well as those in Section 5 There may be other hazards which arise in addi...

Page 4: ...ntee for the accuracy of this data for future production batches All data and figures are subject to a tolerance of 10 unless specified otherwise Warning Under normal conditions a photovoltaic module is likely to experience conditions that produce more cur rent and or voltage than reported at standard test conditions Accordingly the values of Isc and Voc marked on this module should be multiplied ...

Page 5: ...or any other use No liability will be accepted for any damage in cases of different use Improper applications or use particularly refers to Applications which focus light on the surface of the module Applications where the solar modules must comply with requirements for overhead glaz ing or toughened glass which can be walked on or offers fall protection Note Bosch Solar Energy AG s warranty and g...

Page 6: ...mum layout for systems containing μm Si plus EU1510 so lar modules You can find relevant standards and guidelines in Section 4 You should also familiarize yourself with ap plicable local standards guidelines direc tives and official regulations such as techni cal conditions for connecting to the respec tive power supplier s grid handling asbestos roofs lightning protection regulations and fire saf...

Page 7: ...10 modules must not be di rectly connected to previous products such as μm Si plus and μm Si plus EU1310 Warning If μm Si plus EU1510 modules are not installed using the Bosch Solar Rack Slide mounting system a func tional grounding system must be fitted to the module s line conductor see permissible system configura tions All PV strings in a PV system should be built using the same technology sho...

Page 8: ... these considerations Bosch a Si plus solar modules are to be mounted by trained specialists in accordance with recognized technical standards while taking into account applicable industrial standards and regulations Standard DIN 1055 4 Action on Structures contains essential rules for all construction types regarding the planning of the support framework for structures in cluding their foundation...

Page 9: ...r installation and position tolerances When solar modules are installed in an in clined position they must be secured in a suitable way to ensure they do not slip Solar modules must be fastened in such a way that they are free of any stress or distor tion under all operating conditions Mechanical stress which is caused by install ing slightly curved solar modules on a flat plane is permitted Water...

Page 10: ...ems or if you tread on the module 3 4 Transport and storage before in stallation One packaging unit contains 20 solar modules and consists of a two section cardboard box standing on a Euro pallet Instructions on storing modules in transport packag ing No more than two packaging units may be stacked on top of one another i e no more than two units in a stack Do not store in damp conditions Always s...

Page 11: ...rements for fuse links for the protection of solar photovoltaic energy systems IEC 32B 543 CD 2009 Accident prevention regulations Local standards and guidelines i e official regulations on lightning protection Technical conditions for connection required by the respective electric utility 5 Installation 5 1 Safety instructions μm Si plus EU1510 Series solar modules are glass products and convert ...

Page 12: ... aged Do not install any defective modules Note It is strongly recommended to make an immediate re cord of any possible transport damage so that you can make a claim at a later stage 5 4 Module installation Two people are needed to lift the modules out of their packaging and carry them to the installation location Once in the installation location depending on the type of application roof or groun...

Page 13: ...with We ensure that the environment is protected by using the best possible technology and materials while taking finan cial considerations into account 6 1 Packaging We take part in local packaging recovery schemes to ensure that packaging is recycled as effectively as possible All packaging materials are environmentally friendly and re usable 6 2 Disposal Defective or old solar modules must not ...

Page 14: ...in the sub structure such as screws and rails If neces sary re position solar modules or replace the permanently elastic bedding Remove any dirt from solar modules see section on cleaning Check that fastening components such as rails clamps and anti slip devices are se curely in position and if required re fasten securely or replace damaged components according to the installation instructions 7 2...

Page 15: ... Germany Phone 49 361 2195 0 Fax 49 361 2195 1133 sales se de bosch com www bosch solarenergy de Planning and Installation Instructions for the μm Si plus EU1510 Series Bosch Solar Energy AG December 2011 Version ENG 2011 12 We reserve the right to make any changes as a result of technical advances and may do so without prior no tice ...

Reviews: