11 / 60
MKE Synchronous Servomotors
ATEX label
Bosch Rexroth AG
R911414374, Edition 01
3
Scope of delivery
The scope of delivery of a MKE synchronous
motor contains:
•
Motor in original package
•
Additional type plate
•
Operating instructions with safety instruc-
tions
•
Protective coverings for output shaft and
connection points
•
Accompanying papers
On delivery, immediately verify whether the deliv-
ered goods are those specified on the delivery
note. The forwarder must be promptly informed
of any damage on the packaging and goods,
which is detected on delivery. Start-up of dam-
aged goods is prohibited.
4
Explosion protection
4.1
UL E-file number
MKE motors are listed under UL E-file number
E203009. Information can be recalled under
The motors must be operated with the power
control units listed by the manufacturers of the
following manufacturers and series:
Manufacturer
Type / series
Bosch Rexroth
HMS
HMD
HCS
HDD
HDS
DKCXX.3
4.2
Product description
The MKE037, -047, -098, -118 three-phase syn-
chronous motors are used for operation with
drive systems. The motors are flameproof, non-
ventilated, servo-controlled permanent magnet
special motors for use in hazardous areas with a
free internal volume of 300 cu. in. or less. The
motors are controlled by a pulse width modulated
(PWM) variable frequency drive. The speed of the
motor is varied by changing the frequency of the
power supplied. The drive frequency and voltage
are changed by fast pulse width modulation of a
bus voltage. The used current waveform is sinus-
oidal.
The motors are brushless designs with a resolver
or optical encoder.
4.3
ATEX label
Motor classification
MKE037
Class I Division 1 Groups C, D
MKE047
Class I Division 1 Groups C, D
Class II Division 1 Groups F, G
MKE098
Class I Division 1 Groups C, D
Class II Division 1 Groups F, G
MKE118
Class I Division 1 Groups C, D
Class II Division 1 Groups F, G
Surface temperature
The T-code identifies the maximum absolute
motor surface temperature that develops under
all operating conditions. Surface temperature of
motors will not exceed the following UL and CSA
maximum values under fault conditions.
Maximum surface temperature of motor
T-Code
°C
°F
T4
+135
+275
Labeling on the motor:
Specialty Motor for Hazardous Locations
Only use with Rexroth HCS,HDD,HDS,HMD,HMS
or DKCXX.3
Op Temp T4
Instruction and Duty Cycle: See Project Manual
Explosion pr
ot
ection